Troubleshooting
Malfunction
Motion detector without
power
Motion detector does
not switch ON
Motion detector does
not switch OFF
Motion detector keeps
switching ON/OFF
Cause
 Fuse has blown;
not switched ON
Short-circuit
 Twilight setting in
night-time mode dur-
ing daytime operation
 Bulb burned out
 Power switch OFF
 Fuse blown
 Detection zone not
correctly adjusted
 Continued movement
within the detection
zone
 Switched ON light is
within detection zone
and switches ON again
as a result of tempera-
ture change
 Set to continuous
operation by indoor
series switch
 Position Wi-Fi device
very close to the
sensor
 Switched ON light is
within detection zone
 Animals moving in
detection zone
20
Remedy
 Replace fuse, switch
ON mains switch,
check wiring with
voltage tester
 Check connections
 Adjust setting
 Replace light bulb
 Switch ON
 Replace fuse, check
connection if neces
sary
 Readjust
 Check zone and
readjust if necessary
or apply shroud
 Readjust zone or apply
shroud
 Series switch to
automatic
 Increase distance
between Wi-Fi device
and sensor
Adjust detection zone
or apply shrouds,
increase distance
 Adjust zone or apply
shrouds