Herunterladen Inhalt Inhalt Diese Seite drucken

T Roubleshooting; Arranty; S Torage; Isposal Nvironmental Compatibility - SUHNER ABRASIVE ROTOmax 4.2 TWIN Originalbetriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 16
4.2 t
rouBleshooting
Fault messages are depicted in the LED display:
ERR 00: Overload
Reduce load
ERR 01: Excess temperature
fan free
ERR 02: Excess temperature
fan free
ERR 06: Overvoltage. Grinding tool may be too large
Reduce
ERR 07: Undervoltage. The mains voltage is too low
Observe ratings plate
Cable is defective. Plug wired incorrectly
Check
Repair is required for other error code displays. Con-
tact your SUHNER service center and provide the cor-
responding code.
Press the «stop» key to depict the last error code. The er-
ror code is shown after 3 seconds. The current software
version is shown after 6 seconds.
4.3 w

ArrAnty

In the event of the tool being improperly handled, used
for purposes for which it is not intended and/or of the ser-
vice and maintenance instructions not being observed by
non-authorized persons, no warranty shall be in effect for
damages/consequential damages. Complaints can only
be honored if the machine is returned in the undisassem-
bled condition.
4.4 s
torAge
Temperature range: -15°C to +50°C
Max. relative air humidity: 90% at +30°C, 65% at +50°C
4.5 d
/ e
isposAl
nVironmentAl compAtiBility
This machine consists of materials which can be dis-
posed of in a recycling process.
Before disposal, render the machine unusable.
Do not throw the machine into the garbage collec-
tion.
According to national regulations this machine
must be recycled in an environmentally-friendly manner.
32
Allow to cool. Keep
Allow to cool. Keep

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis