Herunterladen Inhalt Inhalt Diese Seite drucken

Technische Daten - BEMKO SES04WH-A Bedienungsanleitung

Infrarot-bewegungssensor
Vorschau ausblenden Andere Handbücher für SES04WH-A:
Inhaltsverzeichnis

Werbung

CONNECTION
Warning! Danger of death through electric shock!
- must be installed by professional electrician
- disconnect power source
- cover or shied any adjacent live components
- check power supply is disconnected
Unload the transparent vinyl cover which is at the bottom of the sensor.
Loose the screws in the connection terminal, and then connect the power to connection terminal of sensor according to connection-wire diagram.
Install back the transparent vinyl cover into the original location.
Fold the metal spring of the sensor upwards, until they are in "I" position with sensor, and then put the sensor into the hole or installation box which is on the
ceiling and has the similar size with the sensor. Releasing the spring, the sensor will be set in this installation position.
After nishing installing, turn on the power and then test it.
STEP 1
TEST
Turn the TIME knob anti-clockwise on the minimum(10s).Turn the LUX knob clockwise on the maximum (sun).
Switch on the power; the sensor and its connected lamp will have no signal at the beginning. After Warm-up 30sec, the sensor can start work .If the sensor
receives the induction signal, the lamp will turn on. While there is no another induction signal any more, the load should stop working within 10sec±3sec and
the lamp would turn o .
Turn LUX knob anti-clockwise on the minimum (3). If the ambient light is more than 3LUX, the sensor would not work and the lamp stop working too. If you
cover the detection window with the opaque objects (towel etc), the sensor would work. Under no induction signal condition, the sensor should stop working
within 10sec±3sec.
NOTE: When testing in daylight, please turn LUX knob to
could not work! If the lamp is more than 60W, the distance between lamp and sensor should be 60cm at
least.
MOST COMMON PROBLEMS AND SOLVING WAYS
The load do not work:
1) Please check if the connection-wiring of power and load is correct.
2) Please check if the load is good.
3) Please check if the working light sets correspond to ambient light.
The sensitivity is poor:
1) Please check if there has any hindrance in front of the detection
window to a ect to receive the signal.
2) Please check if the ambient temperature is too high.

TECHNISCHE DATEN

Stromversorgung
Nennlast
Leistungsaufnahme
Standby-Leistung
Erfassungsreichweite
Umgebungslicht
(SUN) position, otherwise the sensor lamp
230V~ 50Hz
800W
400W
P
: <0.5W
on
P
: <0.5W
sb
Ø8m max (<24°C)
3-2000LUX (adjustable)
STEP 2
3) Please check if the induction signal source is in the detection elds
4) Please check if the installation height corresponds to the height
showed in the instruction.
5) Please check if the moving orientation is correct.
The sensor can not shut o the load automatically:
1) Please check if there is continual signal in the detection eld.
2) Please check if the time delay is the longest.
3) Please check if the power corresponds to the instruction.
DE
Erfassungsbereich
Zeitverzögerung
Arbeitsfeuchtigkeit
Arbeitsfeuchtigkeit
Einbauhöhe
Bewegungsgeschwindigkeit
STEP 3
360º
min: 10s±3s
max:15min±2min
-20~+40°C
<93%RH
max: 2.2m~4m
0.6~1.5m/s

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis