www.electrolux.com
Problem
The compressor does not
start immediately after
pressing the "FastFreeze"
or "FastCool", or after
changing the temperature.
Water flows on the rear
plate of the refrigerator.
Water flows inside the re‐
frigerator.
Water flows on the floor.
Temperature cannot be
set.
dEMo appears on the dis‐
play.
The temperature in the ap‐
pliance is too low/too high.
Possible cause
Temperature set in the
appliance is too low and
the ambient temperature
is too high.
Temperature is set incor‐
rectly.
This is normal, no error
has occurred.
During the automatic de‐
frosting process, frost
melts on the rear plate.
Food products prevent
the water to flow into the
water collector.
The water outlet is clog‐
ged.
The melting water outlet
is not connected to the
evaporative tray above
the compressor.
The "FastFreeze func‐
tion" or "FastCool func‐
tion" is switched on.
The appliance is in dem‐
onstration mode.
The temperature regula‐
tor is not set correctly.
The door is not closed
correctly.
The food products' tem‐
perature is too high.
Solution
Set a higher temperature.
Refer to "Operation"
Refer to "Operation" .
The compressor starts after
a period of time.
This is correct.
Make sure that food prod‐
ucts do not touch the rear
plate.
Clean the water outlet.
Attach the melting water out‐
let to the evaporative tray.
Switch off "FastFreeze func‐
tion" or "FastCool function"
manually, or wait until the
function resets automatically
to set the temperature. Refer
to "FastFreeze function" or
"FastCool function".
Keep the OK pressed for ap‐
proximately 10 seconds until
a long sound is heard and
display shuts off for a short
time.
Set a higher/lower tempera‐
ture.
Refer to "Closing the door".
Let the food products tem‐
perature decrease to room
temperature before storage.