In most cases, the vehicle will start successfully at the first start operation.
4
Some vehicles may need to be connected to the Jumpstarter for 30~120
seconds (At this time, the product will recharge the car battery) to start the
operation. If the vehicle does not start immediately , please wait 20-30
seconds, then try again, no more than 5 consecutive starts within 15
minutes;
After use, please remove the clamps, long press the "Power" button for 2
5
seconds to shut down. The product will shut down automatically without
operation for 60 seconds.
b.Method two: Force Start
(Safety reminder: Some safety protection mechanisms in this mode are invalid
and need to be used with caution. Be sure to prevent the positive and negative
from being connected together to cause a short circuit, otherwise it will lead to
product damage, sparks, and other more serious consequences. You must
check before operation manual)
When the normal start function fails, for example: the voltage of the car battery
1
is very low (the voltage is less than 1V), you can use the forced emergency
start function after checking the operating manual.
Step 1: Insert the Clamps cable connector into the EC8 jumpstart output port
2
of the product.
Step 2: In the power-on state, long press the "BAR/PSI" button for 5 seconds
3
to enter the forced start mode. At this time, the green light on the main
interface will be on, indicating that the jumpstart output is turned on. At this
time, prevent the positive and negative from being connected together to
cause a short circuit; (In this mode, it is required to turn on the forced start
function first, and then connect the clamps to the car battery, otherwise the
output cannot be turned on)
Step 3: Connect the positive and negative of the clamps to the positive and
4
negative of the car battery respectively (there will be a slight spark during the
connection process, which is normal), and make sure that the connection is
good. At this time, the product display screen will display the voltage of the
jumpstarter in parallel with the car battery, and the car can be started;
Short press the "Power" button
5
force start mode.

4.4 How to Use the Voltmeter Function

a. Connect the clamps to the product EC8 jumpstart
output port.