Herunterladen Inhalt Inhalt Diese Seite drucken

Led Light Function; Troubleshooting - Lokithor Aw401 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für AW401:
Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

7. LED Light Function

Press the "LED light control" button for 1 second, the
1
LED light will turn on.
Short press the "LED light control" button to switch
2
modes: light, strobe, SOS, off.
Press the "LED light control" button for 2 seconds to turn the LED light off.
3

8. Troubleshooting

Error
NO.
code
1
100
2
110
3
150
4
160
5
170
6
200
7
310
8
320
9
330
10
410
11
411
12
420
LOKITHOR
Code Explanation
Voltage error
Over-voltage
protection
Over temperature
protection
Low temperature
protection
temperature error
Product problem
Charge and
discharge short
circuit
Charge/discharge
Overcurrent
When inflating, the
current air pressure
is greater than the
set air pressure
Undervoltage
protection during
jumping start
Undervoltage
protection before
Jumping start
Start over
temperature
protection
12
Cause/Solution
Return to factory for repair
Discharge the battery
Wait for the device to cool down
Low temperature environment
which need to increase the
temperature
Temperature environment too
high/low/NTC disconnection or
short circuit
TNeeds to be returned to the
factory for repair
Restart the device
Restart the device
Reset the proper air pressure
Connect the charger
Connect the charger
Wait for the device to cool
down

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis