2
3
4
Note:
After the first self-priming, the pump will redefine the adjustable flow range. The pipeline pressure
will be recorded by the system after the pump running at the set flow/capacity for 3 minutes
without other operation.
During the pump running, if it is detected that the pipeline pressure changes beyond a certain
range, the icon of % or m³/h (or other flow unit) symbol will flash for 5 minutes. If the change last
for 5 minutes, the pump will perform a self-priming and self-learning procedure (see 5.3), and
redefine the flow range accordingly.
After the redefinition of flow range, the pump will automatically adjust the running capacity to
reach the set flow.
5.7 Timer mode
The pump's on/off and running capacity could be commanded by timer, which could be
programmed daily as needed.
1
Enter timer setting by pressing
2
Press
or
3
Press
to confirm and move to time-1 setting
4
Press
or
rate (when % icon is flashing, user can change to set the flow rate by pressing
5
Repeat above steps to set other 3 timers
6
Hold 3 seconds to save setting
7
or
8
The flow rate could be adjusted, by pressing
each step.
The unit of flow rate could be changed to lpm, IMP gpm or US GPM, by
pressing both
Press
to switch to Manual-Inverter mode
to set the local time
to choose the desired running periods, running capacity or flow
Check 4 timers to make sure there is no invalid setting
for 3 seconds (default is m3/h)
or
with 1m³/h for