SYMPTOMS
• After pressing the flush button(24),
the flush does not start
• The cycle is triggered but not much
water flows into the toilet bowl
• The cycle is triggered but no water
flows into the toilet bowl
• The cycle is carried out correctly and
the motor runs, but the water in the
toilet bowl is only removed gradually
or is not removed at all
• The cycle is carried out correctlybut a
lot of water stays in the toilet bowl
• The motor emits a rattling
orcrunching sound, hums, but does
not run
• The motor intermittently activates
• Smells emanate from the washbasin
trap
• The water from the washbasin
does not run out automatically
Warranty: Your waterGenie Compact has a
two year warranty from its day of purchase,
subject to correct installation and usage.
uk
• The electrical power supply is not
active or the electrical power supply
is defective
• The inlet filter on the solenoid
valve (28) is clogged.
• Insufficient water supply flow
• The stopcock is closed
• The solenoid valve (28) is faulty
• Insufficient water supply flow
• The valve flap on the siphon (23) is
leaking
• The drain height is too great.
• The non-return valve is faulty
• Foreign object into the box
• Problem with the motor or the
control system
• The connected sanitary devices are
dripping water
• The non-return valve is faulty
• The washbasin trap is dry
• Washbasin trap blocked
• Problem with the automatic
control
PROBABLE CAUSES
SETMA (Deutschland) GmbH
Siemensstrasse 3
D-85716 Unterschleissheim
Tél. +49 (0)89 / 317 13 19 - Fax +49(0)89 / 317 57 66
REMEDIES
• Restore the electrical supply and
check the electrical power supply
• Otherwise, ask an approved
repair agent to intervene
• Clean the solenoid valve filter
• Modify the installation
• Open the stopcock
• Consult the SFA customer service
• Increase the rinsing time
(programming)
• 6Clean or replace the valve flap on
the siphon (23)
• Modify the installation
• Clean or replace the non-return valve
• Remove the foreign body
• Otherwise, ask an approved repair
agent to intervene
• Check the installation upstream
• Clean or replace the non-return valve
• Install a vacuum breaker
• Remove the foreign body
• Otherwise, ask an approved
repair agent to intervene