Photoelectric Sensors
Red light diffuse reflective energetic BOS 18E-PI-RD30-S4 with IO-Link
Service data
System commands
Index
Data
(dec)
format
0x0002 (2)
System-
UINT8
Command
Profile specific parameters
Index
Subindex
(dec)
0x003B
Teach-In
(59)
Status
0x003C
Set Point
(60)
Value (BDC1)
0x003D
Switch Point
(61)
Configuration
(BDC1)
* Std Hysterese = 5
**Std Threshold = 0x0A (10)
*Plausibility checks
In Window Mode and Two Point Mode SP1 has to be the near and SP2 the far switching point of a BDC.
5
english
Access
Value range
W
0x01 = ParamUploadStart
0x02 = ParamUploadEnd
0x03 = ParamDownloadStart
0x04 = ParamDownloadEnd
0x05 = ParamDownloadStore
0x06 = ParamBreak
0x40 = Teach Apply
0x43 = SP1 Two Value Teach TP1
0x44 = SP1 Two Value Teach TP2
0x45 = SP2 Two Value Teach TP1
0x46 = SP2 Two Value Teach TP2
0x47 = SP1 Dynamic Teach Start
0x48 = SP1 Dynamic Teach Stop
0x49 = SP2 Dynamic Teach Start
0x4A = SP2 Dynamic Teach Stop
0x4F = Teach Cancel
0x80 = Device reset
0x82 = Restore factory settings
Data format Access
(dec)
0x00 (0)
0x01 (1)
Setpoint SP1
UINT16
0x02 (2)
Setpoint SP2
UINT16
0x01 (1)
Switchpoint
logic
0x02 (2)
Switchpoint
mode
0x03 (3)
Switchpoint
hysteresis
*** Std Threshold = 0x05 (5)
Block
Parame-
terization
Teach
Channel
Reset
Value range
UINT8
R
See Smart Sensor Profile
R / W
Std Threshold**
R / W
Std Threshold***
UINT8
R / W
0x00 = N.O.
0x01 = N.C.
UINT8
R / W
0x00 = Deactivated
0x01 = Single point Mode
0x02 = Window Mode
0x03 = Two point Mode
UINT8
R / W
Std Hysteresis*
Remark
Start Block Parameterization Device
Stop Block Parameterization Device
Start Block Parameterization Master
Stop Block Parameterization Master
Stop Block Parameterization Master
and Upload Request
Abort Block Parameterization
Store and accept switching points
Teach TP1 of SP1
Teach TP2 of SP1
Teach TP1 of SP2
Teach TP2 of SP2
Start Dynamic Teach for SP1
Stop Dynamic Teach for SP1
Start Dynamic Teach for SP2
Stop Dynamic Teach for SP2
Abort Teach-In via Teach Channel
Device reset
Reset sensor to factory settings
Remark
Sensor does plausibility
checks for SP1 and SP2
Master
Master
Device
Device
Device
Inhaltsverzeichnis