ATTENTION: If the values of the programming
menu A0 to A4 are changed, the load switch-off no
longer provides any protection! Teach the door operator in
again before re-commissioning. For this carry out
the door operator (Chapter 15) .
Menu
Function, setting range, unit
A0 Length SOFT RUN OPEN in 7cm
0..9
A1 Length SOFT RUN CLOSE in 7cm
0..9
A2 Soft running speed (CLOSE) mm/s
0= 50...9= 140
A3 Backjump, OFF= 0 ON= 1
A4 Change in direction, OFF= 0 ON= 1
Setting (with +/-) only possible if EMERGENCY
STOP plug (1, green) is unplugged.
A5 Added load
1)
OPEN 0..9
A6 Added load
1)
CLOSE 0..9
A7 Door type: Overhead sectional door/one-piece
door = 0
Side sectional door* = 1
Side sectional door with soft start = 2
* Obstruction release also in OPEN direction
If A7 was changed, perform a reset
and then teach in the door operator again.
(Chapter 15).
A8 Warning time (OPEN/CLOSE) 1=2secs...
8=16secs
A9 Accessory card
0= ZKMagicS
1= ZKMagic
b0 Relay 1 (with ZKMagic accessory card)
0= no function
1= E-lock
2= warning light *
3= photo cell test* (interruption transmitter
voltage)
4= status display*: Door in end position OPEN
5= status display*: Door in end position CLOSED
6= green light*
7= red light*
* if A9= 1
b1 Relay 2 (with ZKMagic accessory card)
0= no function
1= E-lock*
2= warning light *
3= photo cell test*
(interruption transmitter voltage)
4= status display*: Door in end position OPEN
5= status display*: Door in end position CLOSED
6= green light*
7= red light*
* if A9= 1
b2 Closing edge protection (accessory card)
0= OFF
1= OSE
b3 Empty run detection 0= OFF 1= ON
b4 Automatic closure function
0= OFF 1= 10 secs2= 30 secs
3= 1 min 4= 2 min5= 3 min
6= 5 min 7= 10 min8= 15 min
resp. plus warning time
18 / 224
Teaching in
Factory setting
2
4
5
1
0
3
3
0
(Chapter 19)
0
0
0
0
0
1
0
1)
IP2285 12/2021
b6 Maintenance interval*
0= OFF
1..9 (1,000 door movements)
Example: 5 = 5,000 door movements
The operator lighting flashes after every door
movement when the maintenance interval has run
out. A misadjustment resets the counter of the
maintenance interval.
b7 Version number: 8 digits are displayed twice in
succession with leading "-".
Example: -04200510 indicates:
Version: 04 Date: 20.05.10
b8 Service mode
0= control panel free, menu items adjustable
1= control panel locked, menu items not
adjustable
2= data output (accessory card)
Setting only possible if EMERGENCY STOP plug
(1, green) and photo cell (2, yellow) are
unplugged.
b9 Run counter: 8 digits are displayed twice in succession
with leading "-".
Example: -00008000 indicates:
8,000 runs
C0 Test mode for Magic-Door-Control (option)
Radio signal, maximum 15 seconds:
0= no signal
1= end position OPEN
2= end position CLOSED
3= run open
4= run close
5= standstill underway
7= error
8= obstruction
1)
If the added load (A5, A6) is >3 and/or the automatic
closing (b4) is set to ON (>0), the door may only be
operated with an additional safety device.
WARNING: to ensure that the closing force value comply with
limits established by the EN 12453 standard für door models
Basematic 42, Superior 42/+42/+42 WIDE with pass door,
Secura with pass door, Comfort with pass door and SSD, the
following parameters values must be set: A1 = 008; A2 = 003
and A6 = 000. This operation must be performed only by
qualified personnel.

19 Reset

ATTENTION: Ther is no longer any protection by
switching off the load after the reset. Teach the door
operator in again before re-commissioning. For this carry out
Teaching in the door operator (Chapter 15) .
Reset (saved values of the teach-in runs)
Press and hold buttons
and menu
one of the 3 status messages A, B or C (see Chapter 10). The
display (r) flashes after a few seconds, then L4 is displayed
and the reset is made.
The remote transmitters are not deleted.
Reset, factory setting
• Pull out plug (1, green).
• During one of the 3 status messages A, B or C (see 10)
press the pushbuttons
and Menu
longer than 12 seconds. The display flashes slowly at first,
then quicker (r). Then the status display reappears, the
0
0
0
simultaneously during
simultaneously for
Magic 600-3