Troubleshooting
SET TEMP. FAN SPEED
MODE
AUTO
25
Indoor/outdoor abnormal
communication
Diagnostic
Abnormality/Protection control
display
H 00
No memory of failure
Indoor/outdoor abnormal
H 11
communication
H 12
Indoor unit capacity unmatched
Indoor intake air temperature sensor
H 14
abnormality
Compressor temperature sensor
H 15
abnormality
Outdoor current transformer (CT)
H 16
abnormality
Outdoor suction temperature sensor
H 17
abnormality
H 19
Indoor fan motor mechanism lock
H 21
Indoor fl oat switch abnormality
Indoor heat exchanger temperature
H 23
sensor 1 abnormality
Indoor heat exchanger temperature
H 24
sensor 2 abnormality
H 25
Indoor ion device abnormality
H 26
Ion generator breakdown abnormality
Outdoor air temperature sensor
H 27
abnormality
Outdoor heat exchanger temperature
H 28
sensor 1 abnormality
Outdoor discharge pipe temperature
H 30
sensor abnormality
H 31
Indoor humidity sensor abnormality
Outdoor heat exchanger temperature
H 32
sensor 2 abnormality
Indoor/outdoor misconnection
H 33
abnormality
18
ACXF55-32681.indb 18
ACXF55-32681.indb 18
12:00,Mon
H11
AUTO
.0
FLAP
AUTO
To retrieve an error code, go to 'System check' and press
or
button until you hear beep sound.
When the display shows an error code as indicated below,
contact the number registered in the Remote Controller or a
nearest authorised installer.
Below is a list of error codes that may appear on the display
when there is some trouble with the system setting or
operation.
keys are disabled.
Error number
Diagnostic
display
H 34
H 35
H 36
H 37
H 38
H 39
H 41
H 50
H 51
H 52
H 58
H 59
H 64
H 67
H 70
H 71
H 72
H 85
H 97
H 98
H 99
Abnormality/Protection control
Outdoor heat sink temperature sensor
abnormality
Indoor drain water backfl ow
abnormality
Outdoor gas pipe temperature sensor
abnormality
Outdoor liquid pipe temperature
sensor abnormality
Indoor/outdoor mismatch (brand code)
Abnormal indoor operating unit or
standby units
Abnormal wiring or piping connection
Ventilation fan motor abnormality
Filter cleaning nozzle lock abnormality
Filter cleaning left-right limit switch
abnormality
Indoor gas sensor abnormality
Eco sensor abnormality
Outdoor high pressure sensor abnormality
nanoe abnormality
Light sensor abnormality
DC cooling fan inside control board
abnormality
PCB temperature sensor abnormality
Abnormal communication between
indoor & wireless LAN module
Outdoor fan motor mechanism lock
Indoor high pressure protection
Indoor operating unit freeze protection