Herunterladen Inhalt Inhalt Diese Seite drucken

Active AGi3500 Benutzerhandbuch Seite 59

Inverter-generator
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

5. OPERATION:
Alternating current (AC) connection.
WARNING:
Be sure all electric devices are turned off before plugging them in.
NOTICE
Be sure all electric devices including the lines and plug connections are in good
condition before connection to the generator.
Be sure the total load is within generator rated output.
Be sure the receptacle load current is within receptacle rated current.
TIP:
Make sure to ground (Earth) the generator. When the electric device is earthed, the
generator must always be earthed.
1. Start the engine.
2. Turn the ESC to "ON".
3. Plug in to AC receptacle.
4. Make sure the AC pilot light is on.
5. Turn on any electric devices.
TIP:
The ESC must be turned to "OFF" before increasing engine speed to rated rpm.
• Most motorized appliances require more than their electrical rating for startup.
When an electrical motor is started, the overload indicator (red) may come on. This is
normal if the overload indicator (red) goes off within 4 seconds. If the overload
indicator (red) stays on, consult your generator dealer.
• If the generator is connected to multiple loads or electricity consumers, please
remember to first connect the one with the highest starting current. And last
connect the one with the lowest starting current.
• If the generator is overloaded, or if there is a short circuit in a connected appliance,
the overload indicator (red) will go ON. The overload indicator (red) will stay ON, and
after about 4 seconds, current to the connected appliance(s) will shut off, and the
output indicator (green) will go OFF. Stop both engines and investigate the problem.
Determine if the cause is a short circuit in a connected appliance or an overload,
correct the problem and restart the generator.
59

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Inhaltsverzeichnis