Herunterladen Inhalt Inhalt Diese Seite drucken

Manual Settings - TFA FUN Bedienungsanleitung

Digitales thermo-hygrometer
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
TFA_No. 30.5050_Anleit_12_22
FUN – Digital thermo-hygrometer

5.1 Manual settings

• Press and hold the SET button for 3 seconds to enter the setting
mode.
5.1.1 Temperature unit setting
• °C flashes in the display.
• Press the + button to change between °C (Celsius) or °F (Fahrenheit)
as temperature unit.
• Confirm with the SET button.
• If you set Fahrenheit as temperature unit, the time will be shown
automatically in 12 hours system (AM/PM) and the date in month/
date sequence (American version).
5.2 Setting DCF reception
• dCF on flashes. By default, the DCF reception is activated (on).
• Press the + button if you want to deactivate the DCF reception (OFF)
or activate again (on).
• Confirm with the SET button.
• Once the DCF time reception is deactivated the clock must be manu-
ally set. No time zone will appear.
26
18.12.2022
18:23 Uhr
Seite 14
FUN – Digital thermo-hygrometer
5.3 Setting of the time zone
• ZOnE 0 flashes.
• The time zone correction is needed for countries where the DCF sig-
nal can be received but the time zone is different from the DCF time
(e.g. 1=one hour plus).
• Press + button to correct the hours for the DCF time (+3/-3).
5.4 Setting of the time and date
• Press the SET button to make the settings in the following sequence:
Hours, minutes, year, month and day. Press + button to adjust it.
• Confirm with the SET button.
5.5 Reset of the maximum-minimum values
• MIN MAX MANUAL flashes.
• Press the + button to select the automatic (AUTO) or manual
(MANUAL) reset mode of the maximum-minimum values.
• Confirm with the SET button.
5.5.1 Manual reset mode
• The maximum and minimum values are only reset manually.
27

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

30.5050.0130.5050.54

Inhaltsverzeichnis