FENCE LEAD AND GROUNDING CHECK

Tip 2
Tip 6
36
1
Check the fence voltage at the end of
the fence power supply cable!
Voltage over 6000 V?
YES
Switch off device, connect
it to the fence and switch on
again
Check the voltage on the
fence with a fence tester.
Over 2.5/4 kV?
NO
2
Check grounding > measure
voltage at grounding post!
Voltage at grounding post
over 1000 V?
YES
Improving the grounding
INSTRUCTION MANUAL VOSS.FARMING SUNNY 200
Checking the fence power supply cable
Tip 5
NO
Supply cable from device to
fence defective
YES
Problem solved
Checking the grounding
Tip 3
The fault is with the fence.
NO
Voltage loss because of poor
connections (knots, corroded
connectors/conductor
materials)
Check the voltage on the
fence with a fence tester.
Over 2.5/4 kV?
YES
Everything is fine
Tip 7
NO
42082 - 01.2022 - V5