Herunterladen Inhalt Inhalt Diese Seite drucken

VOSS.farming Sunny 200 Bedienungsanleitung Seite 34

Vorschau ausblenden Andere Handbücher für Sunny 200:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Error/Problem
Control LED (green) not lit/not
flashing
Device pulses slowly (every 3
seconds)
LED Flashing very fast
Device does not charge via
power supply unit/Defective
power supply unit
Power supply unit flashes red/
green
Drain or short circuit of the
fence supply cable
Voltage on the fence is not
enough
Voltage loss/leakage at the
fence
Poor grounding
34
INSTRUCTION MANUAL VOSS.FARMING SUNNY 200
Solution
Check if the device is switched on.
Check if the battery is charged.
Device is in Eco mode (battery low). Recharge the battery (see
section 10.1).
N OTIC E
Note that when the NIGHT mode is switched on,
the energiser automatically switches to "Eco mode"
at night. If the energiser in NIGHT mode also uses
"Eco mode" during the day, the battery should be
recharged (see section 10.1).
Deep discharge protection is active. Recharge the battery (see
section 10.1)..
Replacement of the power supply unit.
Check if the power supply is correctly connected to the device.
Do not use a conventional cable for the supply line. We
recommend using a high voltage cable (Art. 32611).
Fence length too long. Reduce the area or use a more powerful
device.
Remove vegetation from the fence (mow, cut back).
Check whether the insulators are defective (recognizable by
"cracking" and possibly sparking in the insulator). Replace
defective and weathered insulators.
Check whether the conductor material touches the ground
(e.g. due to breaks, insufficient tension). Repair the fencing,
use only special connectors and tension the conductor
material.
Check if the conductor material has unfavorable properties
(thin conductor, high resistance). Use high quality conductor
material with low resistance and larger diameter. Ensure
high quality wiring of the conductor material.
Make sure that the conductor material is not connected by
knots and that there is adequate connection. Use suitable
connectors for the conductor material.
Follow the tips in section 7.4.
Check whether the ground rod is corroded. Replace corroded
ground rods.
Check that the cables/connections are intact. Replace
defective parts.
42082 - 01.2022 - V5

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

42082

Inhaltsverzeichnis