Sets the operating mode of the channel 2 input of the plug-in receiver.
0: Open
1: Close
2: Step-by-Step
CH2
3: STOP.
Note:
If logic PP=On the settings are relative to bollard 2 only
If logic PP=off the settings are relative to both bollards.
MENU
tca
Enables or disables the automatic ascent time.
Enables or disables the condominium function during descent.
IbL
ON: PP commands wired and radio commands disabled during descent
OFF: function disabled
Enables or disables PP commands from the transmitter during the TCA phase.
IbCA
On: PP commands not enabled.
Off: PP commands enabled.
Enables or disables the condominium function during ascent.
IBC
ON: PP commands wired and radio commands disabled during ascent
OFF: function disabled
Enables or disables the rapid closing.
On: Fast ascent enabled. When the bollard is lowered or during the descent phase,
SCL
the photocell triggers automatic ascent after 3 seconds.
Activate only with TCA=ON
Off: fast ascent disabled.
Enables or disables the simultaneous operation of the bollards.
On: the input DOWN acts a PP input for bollard 1, the UP input acts as a PP input for
PP
bollard 2
Off: the DOWN input operates both bollards during the descent, the UP input oper-
ates both bollards in closing (ascent)
Enables or disables pre-wiring before bollard descent
ON: pre-warning enabled. The flashing output is activated 5s before the start of the
preo
downward motor (do not use with EFO installed)
OFF: Prewarning disabled
Enables or disables the prewarning before the bollard goes UP
ON: Pre-warning enabled. The flashing output is activated 5s before the start of the
preC
downward motor (do not use with EFO installed)
OFF: Pre-warning disabled
Enables/disables timed operation of bollards.
ON: Timed operation of the bollards (the operating time is defined by parameters TM1
nlsu
and TM2).
OFF: operation with limit switch.
Enables or disables the water hammer function.
ON: Function enabled. Before each descent manoeuvre, the control unit commands
ham
a fast descent and ascent manoeuvre to facilitate ice breaking.
OFF: function disabled
Enables or disables the Human Present function.
On: Human Present function.
htr
The DOWN/UP button must be kept pressed throughout the manoeuvre.
Off: Automatic operation.
EFO (Emergency Fast operation) device operation
ON: operation for a bollard equipped with an EFO system. The STOP input becomes
efo
a pressure switch input, the BLINK output controls the valve for the additional tank
(EFO).
OFF: normal operation.
Enables or disables the "forced opening in the absence of mains power" function.
ON: Function active. In the event of a mains power failure the bollard descends auto-
AOPF
matically (see connection diagram ellectrovalve)
NB: the dedicated flashing output for the bollard cannot be used
OFF: Function not active
LOGICS (LOG)
FUNCTION
0-3-(1)
MEMO
ON-OFF-(Default)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)