Rise MAX.CP Installationsanleitung Seite 13

Steuerzentrale für 1 oder 2 poller
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Terminals
Department
1/2/3
Supply
4/5/6
Motor 1
7/8
Blink/EFO E.V.
09/10/2011
Motor 2
12/13
Blink/EFO E.V.
14/15
Auxiliary output 1
16/17
Auxiliary output 2
18/19
24 Vac
20
Not used
21
LSC1
22
LSO1
23
Not used
24
Common Inputs
25
Descent
26
Ascent
27
Photocell
28
STOP
29
LSC2
30
LSO2
31/32
Antenna
FUSES
F1
F10A
F2
F10A
F5
T 100 mA
The various functions are programmed using the LCD display on the control unit and by setting the desired values in the programming
menus described below.
The parameters menu allows a numerical value to be set to a function, similar to an adjustment trimmer.
The logic menu allows a function to be activated or deactivated, similar to the setting of a dip-switch.
Other special functions follow the parameters and logic menus and may vary depending on the type of control unit or software revision.
1 - Press the <PG> button to display the first "PAR" parameter menu.
2 - Use the <+> or <-> button to choose the menu you wish to select.
3 - Press the <PG> button to display the first function available in the menu.
4 - Use the <+> or <-> button to select the function you wish to change.
5 - Press the <PG> button to display the value currently set for the selected function.
6 - Use the <+> or <-> button to select the value you wish to assign to the function.
7 - Press the <PG> button to display the "PRG" signal indicating successful programming.
Pressing <+> and <-> simultaneously within a function menu allows you to return to the top menu without making any changes.
Hold the <+> or <-> button to accelerate the increase/decrease of values.
After 30 seconds, the control unit exits programming mode and switches off the display.
MAX.CP CONTROL UNIT
INPUT/OUTPUT FUNCTIONS (FIG.6)
Description
Input 230Vac 50/60Hz
1: L-phase - 2: N-Neutral - 3: GND-Ground
Bollard connection 1:
4: Descent - 5: COM - 6: Ascent
Output for flashing or EFO device, configurable with EFO logic.
With EFO (Emergency Fast Operation) logic, the device allows a fast ascent time of 1.5
seconds.
Bollard connection 2:
9: Descent - 10: COM - 11: Ascent
Output for flashing or EFO device, configurable with EFO logic.
With EFO (Emergency Fast Operation) logic, the device allows a fast ascent time of 1.5
seconds.
Auxiliary output 1 configurable via parameter AUX1
Voltage free contact max 30Vac/dc 1A.
Auxiliary output 1 configurable via parameter AUX2
Voltage free contact max 30Vac/dc 1A.
Accessory power supply output 24Vac/0.5A max.
Closing limit switch input (bollard up) bollard 1
Opening limit switch input (bollard down) bollard 1
Common for all control inputs.
Button input (N.O. contact), for the descent of bollards, configurable as Clock contact
Button input (N.O. contact), for the ascent of bollards.
Safety device connection input, N.C. contact. (e.g. photocells, magnetic loops, etc.).
STOP button input (N.C. Contact) / configurable with EFO logic
Closing limit switch input (bollard up) bollard 2
Opening limit switch input (bollard down) bollard 2
Built-in radio receiver board antenna connection:
31: ANT-signal- 32: SHIELD-shield.
Motor Protection 1
Motor Protection 2
Transformer Protection/Accessories
PROGRAMMING
TO ACCESS PROGRAMMING
NOTES
13