- If the symbol
DOES NOT appear on the plate, follow
the instructions concerning insulation class I.
Insulation class II
- The appliance has been manufactured as a class II,
therefore no earth cable is necessary. The plug must be
easily accessible after the installation of the appliance.
If the appliance is equipped with power cord without
plug, a suitably dimensioned omnipolar switch with
3 mm minimum opening between contacts must be
fitted between the appliance and the electricity supply
in compliance with the load and current regulations.
- The connection to the mains is carried out as follows:
BROWN = L line
BLUE = N neutral.
Insulation class I
This is a class I, appliance and must therefore be
connected to an effiecient earthing system.
- The appliance must be connected to the electricity
supply as follows:
BROWN = L line
BLUE = N neutral
YELLOW/GREEN =
earth.
The neutral wire must be connected to the terminal
with the N symbol while the YELLOW/GREEN, wire
must be connected to the terminal by the earth
symbol
.
When connecting the appliance to the electricity
supply, make sure that the mains socket has an earth
connection. After fitting the ducted cooker hood, make
sure that the electrical plug is in a position where it
can be accessed easily. If the appliance is connected
directly to the electricity supply, an omnipolar switch
with a minimum contact opening of 3 mm must be
placed in between the two; its size must be suitable
for the load required and it must comply with current
legislation.
• If the hob is electric, gas, or induction, the minimum
distance between the same and the lower part of the
hood must be at least 65 cm. If a connection tube
composed of two parts is used, the upper part must
be placed outside the lower part. Do not connect
the cooker hood exhaust to the same conductor
used to circulate hot air or for evacuating fumes
from other appliances generated by other than an
electrical source. Before proceeding with the assembly
operations, remove the anti-grease filter(s) (Fig.5A) so
that the unit is easier to handle.
- In the case of assembly of the appliance in the suction
version prepare the hole for evacuation of the air.
• We recommend the use of an air exhaust tube which
has the same diameter as the air exhaust outlet hole.
If a pipe with a smaller diameter is used, the efficiency
of the product may be reduced and its operation may
become noisier.
• Fixing to the wall:
- Drill the holes A respecting the distances indicated
(Fig.2).
- Fix the appliance to the wall and align it in horizontal
position to the wall units.
- When the appliance has been adjusted, definitely fix
the hood using the screws A (Fig.3).
For the various installations use screws and screw
anchors suited to the type of wall (e.g. reinforced
concrete, plasterboard, etc.). If the screws and screw
anchors are provided with the product, check that
they are suitable for the type of wall on which the
hood is to be fixed.
• Fixing the decorative telescopic flue:
- Arrange the electrical power supply within the
dimensions of the decorative flue. If your appliance is
to be installed in the ducting version or in the version
with external motor, prepare the air exhaust opening.
- Adjust the width of the support bracket of the upper
flue (Fig.4).
- Then fix it to the ceiling using the screws A (Fig.4)
in such a way that it is in line with your hood and
respecting the distance from the ceiling indicated in
Fig.2.
- Connect the flange C to the air exhaust hole using a
connection pipe (Fig.3).
- Insert the upper flue into the lower flue.
• Filter hood:
Please note:
- In order to transform the hood from EXTRACTOR
HOOD into FILTER HOOD the active carbon filters
must be ordered at your distributor as accessory.
We have two different types of Kit, one with non-
regenerable active carbon filters (Fig.5B) and the
other one with regenerable active charcoal filters
(washable) (Fig.5C).
- To replace the non-regenerable active carbon filters
X, pull lever outwards as shown in Fig.5B.

USE AND MAINTENANCE

• We recommend that the cooker hood is switched
on before any food is cooked. We also recommend
that the appliance is left running for 15 minutes after
the food is cooked, in order to thoroughly eliminate
all contaminated air. The effective performance of
the cooker hood depends on constant maintenance;
the anti-grease filter and the active carbon filter both
require special attention.
• The anti-grease filter is responsible retaining the
grease particles suspended in the air, therefore it is
subject to clogging with variable frequency according
to the use of the appliance.
- To prevent the danger of possible fires, at least every 2
months one must wash the anti-grease filters by hand
using non-abrasive neutral liquid detergents or in the
dishwasher at low temperatures and on short cycles.
- After a few washes, colour alterations may occur. This
does not give the right to claim their replacement.
• The active carbon filters are used to purify the air
that is sent back into the room and its function is to
mitigate the unpleasant odours produced by cooking.
- The non-regenerable active carbon filters must be
replaced at least every 4 months. The saturation of the
active charcoal depends on the more or less prolonged
use of the appliance, on the type of kitchen and on the
frequency with which anti-grease filter is cleaned.
- Regenerable active charcoal filters must be washed
by hand, with non abrasive neutral detergents, or
in the dishwasher at a maximum temperature of
65°C (the washing cycle must be complete without
dishware). Remove excess water without damaging
the filter, remove the plastic parts, and let the mat
dry in the oven for at least 15 minutes approximately
at a maximum temperature of 100°C. To keep the
regenerable charcoal filter functioning efficient this
- 16 -