Maintenance of the UVC
• Check monthly if UV lamp is burning via the UV indicator (i).
• Remove the plugs of the filter and the pump from the socket before carrying out maintenance!
• The outside of the quartz glass (q) should be cleaned twice a year.
• Remove the outer clamp (b) and carefully remove the cover (c) with the UVC from the filter housing (a).
• Carefully clean the quartz glass outer face with a soft cloth and SuperFish Pump & UVC Clean. After cleaning,
thoroughly rinse the quartz glass with clean tap water and check for damage. Replace the quartz glass if it shows
any damage (to prevent glass breakage). Quartz Glass Replacement Kit for TopClear Pro 36000 (Art. 06030135).
• As soon as algae growth increases, check the UVC device and UV-lamp and exchange the UV lamp (m) as needed.
• The UV-lamp should be replaced annually, as the lamp may still show active but no longer emits enough UV
radiation (maximum 8000 operating hours). Replacement lamp for TopClear Pro 36000 UVC: SF UV PL-lamp 55 W
2G11-535 mm (Art. 06011040).
• The lamp is hot, wait 10 minutes after switch off before opening the UVC device.
Fig. F Loosen the two metal screws (r) in the cover and remove the cover plate (c
• Loosen the cable connection (s) of the UVC, unscrew the union nut and pull the plug out of the mating plug.
• Turn the lamp holder (n) anti-clockwise and gently pull the lamp holder with the UV lamp upwards out of the
quartz glass.
• Remove the old UV-lamp (m) with the lamp clip (p) from the fitting of the lamp holder.
• Insert the new UV-lamp in the fitting and put the clip on the UV-lamp.
• Carefully slide the UV lamp back into the quartz glass, check the position of the O-ring (o
holder in a clockwise direction.
Fig. G To replace the quartz glass (q), first remove the lamp holder with the UV lamp.
• Loosen the four screws (t) from the top of the quartz glass and remove the old quartz glass.
• Insert the new quartz glass with both O-rings (o
• NOTICE! The quartz glass can only be inserted in one way. There is a recess in the plastic part of the quartz glass
and a cam in the opening for the quartz glass (on the side of the blue lever).
• Make sure the cam falls into the recess and tighten the screws (crosswise) firmly so that the quartz glass seals
everything and makes it watertight.
• Check the operation of the UVC via the UV control window after you have reinstalled the UV lamp, cable
connection, cover, etc. and switched-on the filter and pump.