Herunterladen Inhalt Inhalt Diese Seite drucken

Diehl IZAR CENTER Einbauanleitung Seite 13

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

English
5.
Instructions
The device must be installed and used in firm
compliance with the specified rules in the pres-
ent technical description.
Any manipulation or installation, that is not properly car-
ried out and does not correspond to the mentioned reg-
ulations, obviates any responsibility on the part of Diehl
Metering. In this case, the responsibility lies solely with
the originator.
The IZAR CENTER should be mounted and put
into operation by qualified experts only.
6.
Installation / removal
Before every installation or removal the power
supply (socket 16, fig. I) must be interrupted.
Install IZAR CENTER
ƒ
Snap the IZAR CENTER onto the hat rail. The black
safety catch (socket 65, fig. I) must point downwards
and engage audibly.
Remove IZAR CENTER
ƒ
Use a pointed object (e.g. screwdriver) and pull the
black safety catch on the lower edge of the IZAR
CENTERs downwards.
IZAR CENTER
- 13 -

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis