Herunterladen Inhalt Inhalt Diese Seite drucken

Velleman WS1060 Bedienungsanleitungen Seite 9

Drahtlose wetterstation mit dcf-uhr und außensensor
Vorschau ausblenden Andere Handbücher für WS1060:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 44
5. Press ALARM to enable/disable the alarm. If the alarm is enabled, the corresponding alarm indicator
HI AL (or LO AL for a low alarm) appear on the display.
6. Press SET to confirm the current setting and go to the next.
7. To return to normal mode, press HISTORY.
High alarm settings
High alarm
Description
Time alarm
Set the time (hours:minutes) when you want the alarm to go off.
Note: you can also set the time alarm via low alarms settings.
Wind speed
Set the wind speed threshold value (0~50m/s). The alarm goes off when the wind speed
is higher than the specified value.
Gust speed
Set the gust speed threshold value (0~50m/s). The alarm goes off when the gust speed
is higher than the specified value.
Wind direction
Set the wind direction. The alarm goes off when the wind comes from the specified
direction.
1 hour rainfall
Set the value of rainfall in 1 hour (0~999.9mm). The alarm goes off when there is more
rain in 1 hour than the specified value.
24 hour rainfall
Set the value of rainfall in 24 hours (0~999.9mm). The alarm goes off when there is
more rain in 24 hours than the specified value.
Outdoor humidity
Set the outdoor humidity value (1%~99%). The alarm goes off when the outdoor
humidity is higher than the specified value.
Outdoor
Set the outdoor temperature value (-40°C~+60°C). The alarm goes off when the
temperature
outdoor temperature is higher than the specified value.
Wind chill
Set the wind chill value (-40°C~+60°C). The alarm goes off when the wind chill
temperature is higher than the specified value.
Dew point
Set the dew point value (-40°C~+60°C). The alarm goes off when the dew point
temperature is higher than the specified value.
Indoor humidity
Set the indoor humidity value (1%~99%). The alarm goes off when the indoor humidity
is higher than the specified value.
Indoor temperature
Set the indoor temperature value (-9.9°C~+60°C). The alarm goes off when the indoor
temperature is higher than the specified value.
Low alarm settings
Low alarm
Description
Outdoor humidity
Set the outdoor humidity value (1%~99%). The alarm goes off when the outdoor
humidity is lower than the specified value.
Outdoor
Set the outdoor temperature value (-40°C~+60°C). The alarm goes off when the
temperature
outdoor temperature is lower than the specified value.
Wind chill
Set the wind chill value (-40°C~+60°C). The alarm goes off when the wind chill
temperature is lower than the specified value.
Dew point
Set the dew point value (-40°C~+60°C). The alarm goes off when the dew point
temperature is lower than the specified value.
Indoor humidity
Set the indoor humidity value (1%~99%). The alarm goes off when the indoor humidity
is lower than the specified value.
Indoor temperature
Set the indoor temperature value (-9.9C~+60°C). The alarm goes off when the indoor
temperature is lower than the specified value.
7.5
Minimum and maximum
The weather station keeps track of minimum and maximum measurements for each weather condition (since
the last reset), together with the time and date when they were recorded.
Displaying minimum and maximum measurements
To display minimum and maximum measurements, proceed as follows:
1. From normal mode, press MIN/MAX.
The station is now in maximum mode. The displays shows the maximum indicator [6].
2. Press + repeatedly to display the maximum values for: wind speed, gust speed, 1 hour rainfall, 24 hour
rainfall, weekly rainfall, monthly rainfall, outdoor humidity, outdoor temperature, wind chill temperature,
dew point, indoor humidity, indoor temperature.
3. Press MIN/MAX to go to minimum mode. The displays shows the minimum indicator [8].
V. 02 – 26/04/2013
WS1060
9
and
©Velleman nv

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis