Phenomenon
Troubleshooting
There's off-flavour source in the room,
There's off flavour
such as furniture, cigarette etc.
There's abnormal
Whether the unit is interfered by thunder,
sound during opera-
radio, etc?
tion
You can heard
Whether the unit is turned on or turned
water-flowing sound
off just now?
E5
Overcurrent protection.
H8
Chassis is full of water.
Malfunction of ambient temperature sen-
F1
sor.
Malfunction of evaporator temperature
F2
sensor.
1. Refrigerant is leaking
F0
2. System is blocked
H3
Overload protection for compressor
E8
Overload malfunction
Outdoor tube temperature sensor is open/
F4
short-circuited.
Never attempt to disassemble or repair the device. Inexpert repairs invalidate the
guarantee and can endanger the users of the device.
Solution
Eliminate the off-flavour source. Clean the
filter.
Disconnect power, put through the power
again, and then turn on the unit again.
There's flowing sound of refrigerant inside
the air conditioner, which is the normal
phenomenon.
Disconnect power, and then turn on the
unit again after 10min. If "E5" still exits,
please contact professional person to
maintain the unit.
1. Pour out the water inside chassis.
2. If "H8" still exits, please contact profes-
sional person to maintain the unit.
Please contact professional person to deal
with it.
Please contact professional person to deal
with it.
1. Re-energize the unit after turning off
and pulling out the plug for 30min;
2. If there's still malfunction, please con-
tact after-sales service.
1.Check if the unit is under high-tempe-
rature and high-humidity environment; if
ambient temperature is too high, power
off the unit and then energize it for ope-
ration after the ambient temperature
drops to 35°C below.
2. Check if the evaporator and condenser
are blocked by some objects; if yes, take
away the objects, power off the unit and
then energize it for operation.
3. If the malfunction still occur, please con-
tact our after-sales service center.
Please contact after-sale service person to
deal with it.