Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

MAINS SWITCH
-Q1
W1 EU
-X1:
1W1
L3
T3
BK or GY
BK3
L3
1W1
1W2
1V1
L2
T2
BK
BK2
L2
1V1
1V2
1U1
L1
T1
BN
L1
BK1
1U1
1U2
3 x 2,1 ² (AWG14)
BU (not used)
XPE1
GNYE
PE
GNYE
*
- XPE4
BOTTOM PLANE
OR
W1 UL/CSA
-X1:
1W1
OG
L3
1V1
RD
L2
1U1
BK
L1
- FT1
WH (not used)
THERMALSWITCH
XPE1
GN(YE)
PE
*
BOTTOM
PLANE
- XPE3
*
MUST BE SHORT CIRCUIT
PROTECTED WITH EXTERNAL
- W3
FUSES ACCORDING TO
LOCAL REGULATIONS
4x1,5mm²
RECIRCULATION MOTOR
ALL WIRINGS 1² (AWG16), EXCEPT OTHERWISE MARKED.
COLOR CODES:
BK = BLACK
FT1: Termal Overload Relay:
BN = BROWN
With Short Circuit Trip.
RD = RED
SETTING RANGES
OG = ORANGE
MAINS SUPPLY:
YE = YELLOW
GN = GREEN
3x200 - 230V / 50Hz.
BU = BLUE
3x200 - 240V / 60Hz.
VT = VIOLET
3x380V / 60Hz.
GY = GREY
3x380 - 415V / 50Hz.
WH = WHITE
3x460 - 480V / 60Hz.
3 x 2,1 ² (AWG14)
BK6
BK5
BK4
1
3
5
1
3
-K1:
CONTACTOR
2
4
6
2
4
5
1
3
- FT1
2U2
2V2
X3:
:1
:2
2
4
6
- W2*
4x2,5mm²
U
V
W
U
V
RD8
:T1
+150
C
- M1
- M2
RD9
:T2
0,16 kW.
3,0 / 3,2 kW
CUTTING MOTOR
W2*
Flexible Conduit for leader protection.
M2: CUTTING MOTOR
MAINS SUPPLY:
Continuous
3x200 - 210V / 50Hz.
2,2 kW.
FT1: SET =
3x220 - 230V / 50Hz.
2,2 kW.
3x380 - 415V / 50Hz.
2,2 kW.
0,4 Amp.
3x200 - 210V / 60Hz.
3,0 kW.
0,4 Amp.
3x220 - 240V / 60Hz.
3,0 kW.
0,23 Amp.
3x380 - 416V / 60Hz.
3,0 kW.
0,23 Amp.
3x460 - 480V / 60Hz.
3,0 kW.
0,20 Amp.
- T1
TRANSFORMER
SEE DRAWNING
No. 14923150
No. 14923160
-K2:
CONTACTOR
6
GNYE
2W2
:3
BOTTOM
PLANE
- XPE10
- XPE14
SAFETY GUARD
CHASSIS
- XPE2
GNYE
W
- XPE11
- XPE5
REAR
BOTTOM
PLATE
PLANE
GNYE
- XPE12
- XPE6
CHASSIS
BOTTOM
PLANE
Time rating 15% 10min.
GNYE
8,2 Amp.
3,2 kW.
14,1 Amp.
8,2 Amp.
3,2 kW.
12,0 Amp.
4,7 Amp.
3,2 kW.
6,8 Amp.
11,0 Amp.
11,0 Amp.
- XPE9
- XPE13
6,5 Amp.
BOTTOM
FRONT
5,3 Amp.
PLANE
PLATE
RD2
F1:S
:11
9,1V
- F1
- S2
2,5 AT
Stop
F1:P
:12
- W4
RD1
BN
:23
24V
- S1
Safety Guard Switch
RD
:24
BU
- W4
RD3
:13
:7
- K1
- S4
START Recirculation.
Contactor
:14
:8
RD4
:22
- K2
Auxiliary
Contact
Blocks
:21
RD5
:95
- FT1
Thermoswitch
:96
RD6
A1
- K1
CONTACTOR
A2
GNYE
BOTTOM PLANE
- XPE8
Recirculation Motor
Contactor.
STRUERS A/S
Rev. A, B:
VALHOEJSALLE 176
Tabel at Cut.motor, change data.
DK-2610 ROEDOVRE
DENMARK
Rev. C:
PHONE: +45 3670 3500
Tabel at Cut.motor,

CIRCUIT DIAGRAM:

insert Time Rating Data.
Change Color at W1 CSA.
Rev. D: 14-01-2005 FTH
W1 wire colors changed
Size
A2
Scale
Friday, January 14, 2005
BK
:11
- S1
Safety Guard Switch
:12
- W4
RD7
:13
:7
- K2
- S3
START Cutting
Contactor
:14
:8
RD8
:34
- K2
Auxiliary
Contact
Blocks
:33
X2
:1
RD8
:T1
- M2
Thermoswitch 140 C
:T2
RD9
:2
X2
RD9
A1
- K2
CONTACTOR
A2
Cutting Motor
Contactor.
Labotom - 3:
CAGE Code
DWG NO
Rev
15323115
D
EK
Sheet
D.E.M.
30.06.98 / DEM
1
of
1

Quicklinks ausblenden: