Herunterladen Diese Seite drucken

Lunos 5/UNI-RF Anleitung Seite 14

Universalsteuerung/zur funkanbindung
Vorschau ausblenden Andere Handbücher für 5/UNI-RF:
Verfügbare Sprachen

Verfügbare Sprachen

Teach-in Procedure / System Setup
The slave component is assigned to a ventilation group (group 1 or
2) via DIP switch 2. This assignment is used to configure which
components work together in supply air mode and which work in
exhaust air mode. The master is automatically assigned to group 1.
After all components have been set up and the teach-in process
has been completed, an identical number of fans should be assig-
ned to both groups.
1.
Master Installation and configure according to the
respective instructions (5/SC-FT or 5/UNI-FT).
2.
Master Hold down the internal button for 5 seconds.
The red LED starts flashing.
3.
Slave Set the coding switch to position 0. Set DIP 2 to 0
(group 1) or - (group 2).
4.
Slave Keep internal button pressed for 5 seconds. The
red LED / Event LED starts flashing.
5.
Master and Slave Both report a successful teach-in
process with the green LED flashing three times or the
Event LED stops flashing.
6.
If necessary, continue with point 2 for the next slave.
14
EN
loading