Lift the unit onto the cab. To lift the unit, it
7
is recommended to use (3) suction lifters
reference 1486986.
Carefully place the unit on the hatch opening,
making sure the silicone bead on the cab roof
does not move. From inside the cab, use the
aligners on the corners of the base of the unit
to place it in its correct position. Make sure the
unit's 3 positioners are placed in their holes
in the chassis. Pass the recirculation sensor
connector (A) into the cab before fully resting
the unit.
Caution: If the silicone bead on the roof
is displaced during installation of the unit,
the unit must be completely removed and
the silicone reapplied. Displacement of the
silicone bead may cause water to enter the
cab.
Press the unit against the roof until the
8
stoppers in the base come into contact with it
and the roof's silicone fits with the base of the
unit to form a watertight seal.