Clean the edge of the hatch where the unit will
5
rest, and apply Sika Aktivator 100 activator
(reference 1312362).
Apply Sika Flex 260N silicone (reference
6
1286577) on the edge of the hatch where the
activator was applied. To ensure Sika Flex
260N is applied correctly, cut the diffuser
nozzle into a triangular shape as shown in the
image, obtaining a triangular-shaped bead of
silicone measuring at least 11 mm wide by 16
mm high.
Important: Do not cover the unit's positioning
holes in the cab chassis with silicone.
Caution: If the silicone bead does not comply
with the recommended dimensions of 11
mm wide x 16 mm high, water may enter the
vehicle cab.