4. Technical specifications
Connection voltage
Range
Air volume
Air speed
Discharge (s)
Measured at the center of the
airflow
Regulation
Air warming
Working environment
Noise level
Usage
Ozone production
Accessoires
See spare parts list
5. Installation
Warning:
- Electrical installation must be done by an electrically qualified person.
- When working on the equipment, the power supply must be completely disconnected.
- The appliance must be properly grounded. Grounding is necessary for proper
operation and prevents electric shock if touched.
5.1 Control
- Check that the XC has been received undamaged and is the correct type.
- Check that the packing slip information matches the information of the received product.
- Check whether the voltage on the type plate corresponds to the mains voltage you are using.
In case of problems and/or questions, please contact Simco-Ion or the agent in your region.
XC_UM_9752065910_NL_D_GB_FF_V1_1
230 V AC, 50 Hz, 0,3/1,8 A (heating on/off)
120 V AC, 60 Hz, 0,6/3,6 A (heating on/off)
0,3 – 1 m
3
Speed low: 120 m
Speed low: 1,5 m/s, medium: 2 m/s, high 2,5 m/s
Measured from 60 cm distance in the center of the air flow
Speed
@30 cm @60 cm @75 cm @100 cm
Low
2,2
Medium
1,9
High
1,6
Automatic 0 ±5V
Speed high and medium: +2-3°C, speed low: +3-4°C
relative to the ambient temperature, at a 30 cm distance
10 - 35°C, humidity 30 - 70%, non condensing
Speed low: 52 dB, medium: 58 dB, high: 64 dB
measured at a distance of 60 cm
Industrial, indoor usage
0,005 ppm, measured at a 15 cm distance
- Air filter set: slide-in filter with mounting material
- Filter material: open cell Polyurethane foam 30 ppi
- Elevated pedestal
/h, medium: 160 m
5,5
7,7
3,8
5,5
2,7
4,4
3
3
/h, high: 175 m
/h
9,9
7,7
6,0
25