Herunterladen Inhalt Inhalt Diese Seite drucken

S&P TD-250/100 SILENT Bedienungsanleitung Seite 12

Vorschau ausblenden Andere Handbücher für TD-250/100 SILENT:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 19
vice, which will function as the "designated"
disconnect device must be provided, and:
1) It shall disconnect the "Line", while dis-
connectionof the "Neutral" is optional;
EN
2) Its OFF-position shall be clearly marked;
3) Not to position the equipment so that it is
diffi cult to operate it; and
4) The protection current device must be at
least 10A, 250V, curve Type C.
TRANSPORT, LIFTING
• Fan equipment and packaging are protected
from adverse atmosphere, especially water,
sand, dust, vibration and excessive temper-
ature. The packaging used for this fan has
been designed to support normal transport-
ing conditions.
• The fan must always be transported in its
original packaging. Do not accept delivery
if the fan is not in its original packaging or
shows clear signs of having been damaged.
• Do not place heavy weights on the packaging
and avoid impact damage.
• Any lifting equipment must be safe and of
suitable capacity for weight and size. Spe-
cial attention may be required to ensure fan
assembly does not distort or tilt as weight
distribution may vary.
• When Fan equipment is carefully lowered or
placed on a surface, be it temporary, during
lifting, positioning, storage or permanent,
this must be a fl at surface to avoid distortion
of fan casing or fan assembly.
STORAGE
Storage must be in a safe, fl at, controlled en-
vironment to prevent damage, especially from
water, sand, dust, moisture, corrosion, tem-
perature. Recommend that duct connections
(infl ow and outfl ow) are closed to avoid dust/
debris entering the equipment.
These data may also apply to an installed fan,
which is not put into operation for extended period.
INSTALLATION
Fan equipment should be electrically isolated
and locked out before any work started.
12
Before any installation work is started, ensure
that fan equipment is correct for application.
Location for installation is solid, level, fl at and
suitable for mounting fan assembly.
Fan should be located in position, and assem-
bled with any accessory equipment supplied,
on relevant mounting, anti-vibration mount-
ings, safety protection guards, on a solid level
base to avoid any distortion and misalignment
and with correct air direction as shown on
nameplate. Fan should then be leveled on any
anti-vibration mountings. Flexible connectors
must be taught to ensure no disruption to air
fl ow, especially on inlet to fan.
START UP
• Check fan equipment name plate data is
appropriate to the location electrical supply,
especially Voltage, Frequency, Phase, Amps,
speed are correct.
• Check earth connections, electrical termi-
nations and terminal box lid, with any seals,
if fi tted, are correct.
• In compliance with Machine Directive, if the
fan is accessible to operators and is a health
and safety risk, adequate protection must
be fi tted, information for safety equipment,
including guards, can be found in S&P ac-
cessories catalogue.
• Check all rotating parts have free, unob-
structed movement.
• Check there are no foreign bodies inside the
fan or that can be drawn into, or fall into fan.
• Check the structure is complete and has no
damage.
• Check installation and area is safe and ener-
gise fan and start motor. Check that the im-
peller and airfl ow direction is correct, check
current does not exceed fan equipment
nameplate data.
• After two hours of operation, check that all
fi xings are tight and adjust if necessary.
This appliance is considered to be
suitable for use in countries having a
warm damp equable climate as spe-
cifi ed in IEC 60721-2-1. It may also be
used in other countries.