Herunterladen Inhalt Inhalt Diese Seite drucken

Oase Varionaut 270 DMX/02 Gebrauchsanleitung Seite 20

Vorschau ausblenden Andere Handbücher für Varionaut 270 DMX/02:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

- EN -
Install the unit at a dry place
 C
• Swimming pond or pool that may be accessed by people.
– Install the unit at least 2 m away from the water.
• Do not expose the unit to direct sunlight.
• Ensure that the pump is in a secure and stable position.
• The position of the pump outlet can be changed. The pump casing has to be turned to achieve a different position.
(→ Turning the pump casing to achieve a different position )
How to proceed:
 E
1. Remove the screws for fastening the filter basket and remove the filter basket.
2. Place the pump with stand in a horizontal position on a suitable base and bolt down.
3. Connect the suction line to the inlet.
4. Connect the pressure line to the outlet.
Turning the pump casing to achieve a different position
How to proceed:
 F
1. Remove the screws for fastening the filter basket and remove the filter basket.
2. Remove the screws for fastening the stand and remove the stand.
3. Remove the four screws for fastening the retaining plate and remove the retaining plate.
4. Remove the four screws and take off the pump casing.
5. Turn the pump casing, place it onto the motor and fasten with the four screws.
– The pump casing can only be mounted in the two positions indicated.
6. Fit the retaining plate onto the pump casing and fasten with the four screws.
7. Place the pump on the stand and fasten with the screws.
8. Fit the filter basket and screw tight.
Connecting the DMX connection cable
A maximum of 31 end devices may be connected to one DMX bus.
How to proceed:
 G
1. Remove the protection cap from the unit.
2. Fit the plug connector and secure with the two screws (max. 2.0 Nm (max. 18 lb-in)).
– Ensure that the rubber seal is clean and fits exactly.
– Replace the rubber seal if damaged.
AMX0034
Commissioning/start-up
• A DMX/RDM controller can be used for commissioning/start-up and operation.
• The DMX / RDM protocol is used for signal transmission and control.
• For programming, refer to the controller documentation.
Switching on the unit
Switching on:Establish an electrical connection and transmit the DMX control signal.
Switching off: Transmit the DMX control signal and disconnect the electrical connection.
20
Note!
The device will be destroyed if water penetrates the DMX/RDM sockets.
• Ensure that the DMX/RDM sockets are closed off by the DMX/RDM plug or pro-
tection cap.

Werbung