Herunterladen Inhalt Inhalt Diese Seite drucken

Continuity Testing; Diode Testing - PeakTech 4350 Bedienungsanleitung

True rms stromzange
Vorschau ausblenden Andere Handbücher für 4350:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

All manuals and user guides at all-guides.com

6.4. Continuity testing

CAUTION!
Measurements must only be made with the circuit power OFF.
1. Select the Ω/
switch.
)
)
2. Select
)
by pressing MODE-button.
°
3. Follow step 2 and 5 as for resistance measurements.
4. An audible tone will sound for resistance less than approx. 50
. After all measurements are completed, disconnect the test
leads from the circuit and from the input terminals.

6.5. Diode testing

CAUTION!
Measurements must only be made with the circuit power OFF.
1. Set the rotary selector switch to the Ω/
2. Select
3. Follow steps 2 and 5 as for resistance measurements.
4. The red test lead should be connected to the anode and the
black lead to the cathode. For a silicon diode, the typical
forward voltage should be about 0,7 V or 0.4 V for a
germanium diode.
5. If the diode is reverse biased or there is an open circuit the
display shows "OL".
)
)
/
)
position by turning the rotary selector
°
by pressing MODE-button
/
37
)
)
)
position.
°

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis