Herunterladen Inhalt Inhalt Diese Seite drucken

Safety Classification; Mounting; General Mounting Instructions; Dimensions - schmersal SHGV/L01 Serie Betriebsanleitung

Schlüsseltransfersystem
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Operating instructions
Trapped key system

2.5 Safety classification

Solenoid interlock
Standards:
MTTF
:
d
B
:
10d
Service life:
Key-operated selector switch
Standards:
B
(NC contact):
10d
Service life:
Key-operated selector switch-interlocking device SVE
Standards:
B
(NC contact):
10d
Service life:
Key distribution station
Standards:
B
:
10d
Service life:
B
10d
MTTF
d
0,1 x n
op
(Specifications can vary depending on the application-specific
parameters h
, d
op
op

3 Mounting

3.1 General mounting instructions

Interlocking device
Four mounting holes are provided for fixing the switch. When used in
applications with function for the protection of man, the components
must be fitted so that disassembly is prevented (e.g. drill out the
hexagonal recess of the fixing screws, blocking the hexagonal recess
using a plastic cone).
The solenoid interlock must not be used as an end stop. Any mounting
position. The mounting position however must be chosen so that the
ingress of dirt and soiling in the used opening is avoided. For the lock
barrel, the SHGV-SK dust-proof flap (accessory) can be used as
required.
In case of painting activities, the components must be covered. Turn
the actuating head in the desired direction and retighten the screws
(tightening torque 0.5 Nm). The default screws installed in the actuating
head can be replaced with the supplied tamperproof screws. The
actuator must be inserted when the actuating head is turned.
Key-operated selector switch
Mount the key-operated selector switch in the provided mounting hole
Ø 22.3 by means of the mounting flange, align and tighten.(tightening
torque: 0.6 Nm). Snap the contact elements onto the mounting flange.
Check for a correct and firm fixation of the elements. Any mounting
position. The mounting position however must be chosen so that the
ingression of dirt and soiling in the lock barrel is avoided. Use the
SHGV-SK dust-proof flap (accessory) if necessary.
Key-operated selector switch-interlocking device
Six mounting holes are provided for fixing the device. When used in
applications with function for the protection of man, the components
must be fitted so that disassembly is prevented. Any mounting position.
The mounting position however must be chosen so that the ingression
of dirt and soiling in the lock barrel is avoided, use the SHGV-SK dust-
proof flap (accessory) if necessary. In case of painting activities, the
components must be covered.
mrl_shgv-sve-svm_de-en.indd 13
EN ISO 13849-1
150 years; when a single switch is used,
suitable up to PL d (when used in PL d,
fault exclusions must be guaranteed)
100,000
20 years
EN ISO 13849-1
100,000
20 years
EN ISO 13849-1
100,000
20 years
EN ISO 13849-1
100,000
20 years
d
x
x
3600
s/h
h
n
op
op
op
t
cycle
and t
as well as the load.)
cycle
Key distribution station
Four mounting holes are provided for fixing the device. When used in
applications with function for the protection of man, the components
must be fitted so that disassembly is prevented. Any mounting position.
The mounting position however must be chosen so that the ingression
of dirt and soiling in the lock barrel is avoided, use the SHGV-SK dust-
proof flap (accessory) if necessary. In case of painting activities, the
components must be covered.
Please observe the remarks of the standards
EN ISO 12100, EN 953 and EN 1088.

3.2 Dimensions

All measurements in mm.
Interlocking device
31
30
40
SHGV/R01/...; SHGV/L01/...; SHGV/B01/...
31
20
30
40
47
SHGV/RD1/...; SHGV/LD1/...
31
40
30
SHGV/R1.1/...; SHGV/L1.1/...; SHGV/B1.1/...
EN
SHGV / SVE / SVM
1)
24
16
32,3
20
47
41
43
1)
16 24
32,3
41
43
1)
16 24
20
47
41
43
13
10.03.2010 15:31:35

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis