Herunterladen Inhalt Inhalt Diese Seite drucken

Hama EWS-1100 Bedienungsanleitung Seite 5

Elektronische wetterstation
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
rainy
stormy
To obtain an accurate weather forecast & barometric pres-
sure reading, you need to input your current altitude. After
the reset of the unit, it will enter the altitude setting mode.
Press "
" or "
" to set the unit first, and then press
"PRESSURE" and enter your current altitude. Press
"PRESSURE" to confirm and exit the setting. You can also
hold "PRESSURE" button to enter altitude setting mode
during normal use.
Press PRESSURE button to select pressure unit between
hPa, inHg & mb.
IN/OUT temperature & humidity
Temperature reading is located on the lower left of the
display and humidity is on the lower right.
Press "C/F" button to select temperature unit C/ F.
Press CHANNEL/SEARCH button to select indoor, Ch1, Ch2,
Ch3 and auto-channel scrolling display modes.
IN/OUT heat index
Heat Index combines the effects of heat and humidity. It
is the apparent temperature of how hot the heat-humidity
combination makes it feels.
Press "Heat Index/Dew Point" button once to show the
respective indoor or outdoor heat index on the lower left
display. "HEAT INDEX" icon will appear.
IN/OUT dew point
Dew point is the saturation point of the air, or the
temperature to which the air has to be cooled in order to
get condensation.
In normal mode, press HEAT INDEX / DEW POINT button
twice to show the respective indoor or outdoor dew point
reading on the lower left display. "DEW POINT" icon will
appear.
IN/OUT comfort level
In/Out Comfort indicator combines the effect of temperature
& humidity and displays in 3 levels:
8
COMF : Comfortable level, ideal range for both temperature
& humidity
WET : Contain excess moisture
DRY : Contain inadequate moisture
Colour bar graphs
The color graphs are designed as an intuitive way to gauge
the weather at a glance. The left color bar graph represents
the respective In/Out temperature, heat index or dew point
of the current display mode. The right graph represents the
respective In/Out humidity. As the measurements change,
the number of illuminated bars changes automatically.
Maximum/Minimum memory
Press MEMORY button repeatedly to view the maximum &
minimum values of temperature, humidity, heat index or dew
point readings. To clear the memory record, hold MEMORY
button while the respective values are displaying on screen.
Temperature & humidity trend indicator
The icons will indicate Rising, Steady, Falling if the
temperature or humidity change is more than 1 degree C
(or 2 degree F) within an hour.
Clock & calendar
Press "CLOCK" to toggle display between time, calendar
and day of the week.
Hold "CLOCK " button to enter clock setting mode. Using
"
" or "
" to adjust and "CLOCK" to confirm, the
following values can be set in sequence:
12/24hr format > Hr > Min > Yr > D/M or M/D format > Month
> Date > EXIT
Moon phase
Moon phase is displayed according to the current calendar.
Home time, world (zone) time
Hold "ZONE" to enter world (zone) time setting mode. Press
"
" or "
" to enter the desired hour offset value from
–12 to +12 hours. Press "ZONE" to confirm each setting.
Press "ZONE" button to toggle between home
(radio- controlled) time and world (zone) time. "ZONE" icon
appears when world (zone) time is selected. When zone
time is not used, set zone time to "0".
Alarm setting
Press "ALARM" to show alarm time and "AL." icon will
appear. Press again to enable or disable the alarm. Bell icon
"%" appears when alarm is enabled.
Hold "ALARM" to enter alarm time setting mode. Press
"
" or "
" to enter the desired Hr/ Min values and press
"ALARM" to confirm setting.
Snooze & backlight
When alarm is going off, press SNOOZE/ LIGHT to trigger
snooze alarm and "Zz" icon will appear. To stop alarm for
one day, press "ALARM" key. Press SNOOZE/LIGHT for an
extended backlight if adapter is not connected.
Low battery indication
Low battery indication is available for the home unit itself
and all of the 3 remote channels. Replace the batteries and
follow the setup procedure in this instruction manual.
Battery disposal
Replace only with the same or equivalent type
recommended by the manufacturer.
Please disposal of old, defective batteries in an
environmentally friendly manner in accordance with the
relevant legislation.
Specifications
Indoor Temperature: 0 C to + 50 C (+32 F to +122 F)
In/Out Humidity: 20% - 99% RH
Remote sensor: -20 C to +60 C (-4 F to +140 F)
Channel: max. 3 remote sensors
Transmission: up to 75M (246 ft.) in open area, RF434 MHz
Resolution: 0.1 degree C for temperature,
1% for humidity
Clock: DCF77 Radio-Controlled, Quartz back-up
Power: 4.5V adapter & AAA x 3 pcs for main unit
AAA x 2 pcs for remote sensor
Registration and Safety Certification/General Information
This device bears the CE symbol as specified by the
provisions of Directive R & TTE (1999/5/EC).
Hama GmbH & Co. KG hereby declares that this device is in
compliance with the basic requirements and other relevant
guideline and regulations of the 1999/5/EC guideline. You
will find the declaration of compliance and declaration of
conformity in the Internet at http://www.hama.com
9

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

00087685

Inhaltsverzeichnis