Balluff Network Interface EtherNet/IP™
6
Configuration via Explicit Messages
Example with
Rockwell
Components
www.balluff.com
Source:
Allen-Bradley Ethernet/IP QuickConnect Application Technique, Page 12
Please also note the following:
Direct connection between PLC and QuickConnect slave with crossover cable
Slave-to-slave connection using patch cable
For setting up the topology, only the linear topology with a maximum of 20 modules
on the tool side is permitted.
If needed, only one managed switch may be used between the PLC and Ethernet/IP
slave.
To trigger the QuickConnect sequence, an electrical lock signal is required that
reads in the supply voltage of the QuickConnect slaves via the controller.
22