If several devices are interconnected (section Setup) the slave units can be synchronized and controlled with the
master unit without the need for a DMX controller. The devices must be set to the corresponding operating modes.
1
Set the DIP switches 1 and 10 on the slave units to the upper position (ON).
2
Set the master unit to the desired control program. All devices will now operate in sync.
For control via a lighting controller with DMX512 protocol, the device is equipped with five DMX control channels.
Channel
Value
1
000 – 255
2
000 – 255
3
000 – 255
4
000 – 255
000 – 000
001 – 005
5
006 – 010
011 – 255
DMX connection
1
Connect the output of your DMX controller to the DMX input of the first fixture with an XLR/jack adapter cable
(optional).
2
Connect the DMX output of the first fixture to the DMX input of the next fixture in the chain. Always connect one
output to the input of the next unit all fixtures are connected.
Note: To avoid errors during data transmission, the DMX cable should be terminated at the last fixture using a
terminator (optional).
MASTER/SLAVE OEPRATION
DMX OEPRATION
Brightness red (0 – 100%)
Brightness green (0 – 100%)
Brightness blue (0 – 100%)
Total Brightness (0 – 100%)
On
Off
On
Strobe effect with increasing speed
Adapter cable (optional)
Function
included jack cable