04 - INSTALLATION

• Place the heater on a flat, level, non-combustible, solid surface.
• Direct-fired heaters are intended for use outdoors or in well-ventilated indoor areas. For indoor
use, provide permanent ventilation openings of at least 250 cm², evenly distributed between floor
and height.
• Install the heater only in a normal, upright position.
• Do not place the heater near walls, corners or low ceilings.
• Do not place the heater below an electrical outlet.
• Do not place the heater on top of moving vehicles or where it may tip over.
• Keep the heater away from flammable, combustible, explosive or corrosive materials.
• Keep the heater away from curtains or similar materials that could block the air inlet and outlet.
• Never block or restrict the air inlet and outlet for any reason.
• Keep the power cord away from heat sources, sharp edges, cutting and moving parts.
• Do not expose the heater directly to the weather or excessive moisture.
• Do not place the heater in a humid environment.
• Observe the general and special fire protection regulations that apply in all areas of application.
In any case, maintain the following minimum safety distances from materials or objects in the
vicinity of the heater:
Side: 2 m
Air inlet side: 2.5 m
Top side: 2 m
Hoit air outlet side: 3.5 m
Bottom: 0 m
• Floors and ceilings must be made of fireproof materials at the heater's place of use.
• Do not connect directly fired heaters to air ducts.

05 - HOW TO USE

Commissioning
1. Inspect the heater for possible shipping damage.
2. Connect the hose and regulator assembly to the LPG cylinder by turning the nut counterclockwise
into the valve outlet of the LPG cylinder and tighten firmly.
3. Open the cylinder gas valve and check all gas connections with a soapy water solution.
4. Connect the power cord to a well grounded 220-240V~, 50Hz power source.
CAUTION
If ignition is difficult or erratic, make sure the blower is not blocked and the air inlet and outlet are
not blocked before repeating the ignition procedures.