EN

PRODUCT DESCRIPTION

1 Display
2 Air outlet cover
3 Appliance body
4 Lower grille
5 Filter
6 Appliance base
INSTALLING THE FILTER
Turn the filter base counterclockwise (Fig. 1).
Insert the filter.
Insert the base back and turn it clockwise.
USE
TIMER: When the appliance is running, the operating time can be set using the "timer" button. Set the time to 1 hour, 2 hours, 3 hours, press again to turn off,
the corresponding indicator lights up after the selected time.
Fan speed: Press the fan speed button to change the speed (1-3).
RESET: The appliance is equipped with a filter replacement alert function. When the filter replacement indicator lights up, replace the filters. Then hold the
button for 3 seconds and the countdown will reset.
Ionization: Use the ionization on/off button to switch ionization on or off.

INSTALLATION INSTRUCTIONS

In case of internal dust, such as pollen, the appliance should be placed on the ground. Since pollen, dust, etc. are usually held close to the floor, it is
recommended to place the purifier on a flat floor in the room.
In order not to block the air inlet and outlet, place the appliance about 30 cm or more away from the left and right sides of the wall, furniture, curtains,
etc. For effective use of the appliance, please keep it at least 20 cm away from the wall behind it.
Do not place any objects on the top of the appliance (this may cause the appliance to malfunction).
Note: Do not place magnets or metal objects on the appliance.
Do not block the air inlet and outlet, for example, do not place any objects on the air outlet. Or on the front side, on the air inlet.
MAINTENANCE
Disconnect the mains supply before cleaning and maintenance.
Place the filter in a ventilated area so that harmful gases and bacteria on the filter surface can evaporate. Do not expose it to excessive sunlight.
Do not wash the filter with water.
Do not work with the filter removed (operation without the effect of removing dust may cause the appliance to malfunction).
If the appliance is idle for a long time, unplug the power cord (it also consumes power in standby mode).
TROUBLESHOOTING
Common faults, error code description and troubleshooting method.
Problem
It is not possible to turn on or press the
button, no response
The odour from the appliance outlet is
unpleasant
The purifier runs for a long time, but the air
quality does not improve significantly
20
Control panel
A Ionization on/off
B Light
C Fan speed
D Wi-Fi symbol
E On/off button
F Timer
G Filter restart
Cause
Is the power cord plugged in?
Is the filter installed correctly?
The filter indicator is on: this means that the
filter replacement timer has reached the
set value.
Remedy
Plug in the power cord.
Follow the installation instructions and
precautions.
After replacing the filter, press the button to restart
the filter.