Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting - Endress+Hauser Soliwave M FQR50 Bedienungsanleitung

Mikrowellenschranke
Vorschau ausblenden Andere Handbücher für Soliwave M FQR50:
Inhaltsverzeichnis

Werbung

Fault
Reason
Does not switch
No power or power too low
on (LED output
(green LED does not light
off)
up)
Emitter defective
Attenuation of the product
too high
Path of rays covered (e.g.
PTFE-diaphragm dirty)
Wrong installation (from
page 17)
Does not switch
Receiver defective
off (LED output
Attenuation of the product
on)
too low
Endress+Hauser
Remedy
Check power at the emitter and
receiver
Replace emitter
Adjust the sensitivity at the
receiver (see page 33)
Clean path of rays
Check installation
Replace receiver
Adjust the sensitivity at the
receiver
en - Troubleshooting
33

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Diese Anleitung auch für:

Soliwave m fdr50

Inhaltsverzeichnis