Electrical Specifications

Accuracy is given as ±(% of reading + counts of least significant
digit) at 23°C ± 5°C, with relative humidity Less than 80% R.H.
1. Temperature coefficient
0.1 x (Specified accuracy) / °C, < 18°C, > 28°C
2. AC Function
ACV and ACA specifications are ac coupled, true R.M.S. The
crest factor may be up to 3.0 as 4000 counts.
For square wave, Accuracy is unspecified.
For non-sinusoidal waveforms, Additional Accuracy by Crest
Factor (C.F.) : Add 3.0% for C.F. 1.0 ~ 2.0.
Add 5.0% for C.F. 2.0 ~ 2.5.
Add 7.0% for C.F. 2.5 ~ 3.0.
3. DC mV
Range
600.0mV
Input Impedance :
Overload Protection : AC/DC1000V
4. DC Voltage
Range
OL Reading
6.000V
60.00V
600.0V
1000V
Input Impedance :
Overload Protection : AC/DC 1000V
OL Reading
Resolution
660.0mV
Resolution
6.600V
66.00V
660.0V
1100V
14
Accuracy
0.1mV
±(0.5% + 5D)
Accuracy
0.001V
0.01V
±(0.5% + 2D)
0.1V
1V