Herunterladen Inhalt Inhalt Diese Seite drucken

Installation Instructions; Cable Connection Between Boiler And Control Panel - Alde 3010 613 Montageanleitung Und Bedienungsanleitung

Bedieneinheit
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 19
INSTALLATION INSTRUCTIONS CONTROL PANEL 3010 613
Control panel 3010 613 is intended for the Alde Compact 3010 boiler.
The control panel should be located at least 1 metre above the floor, but not too close to the ceiling. Nor should it be
enclosed, located on an outer wall or close to objects which radiate heat, for example, CD players, refrigerator and
lamps, as this can give incorrect temperature. The area behind the panel should be well ventilated. If the room tem-
perature on the panel is affected nevertheless, an external sensor should be connected to the panel.
Make a hole for the panel as shown in figure C. Screw down the panel and push the front part on. Clip on the cables to
avoid wear on the terminal strip of the panel.
A.
86 mm
CABLE CONNECTION BETWEEN BOILER COMPACT 3010 AND CONTROL
PANEL 3010 613
Connect accessories to the control panel as shown in the diagram below. N.B. Do not cramp 12 V cables or sensor
cables together with 230 V cables. It is preferable not to place the cables close to each other. If the cables are bund-
led, the risk of shutdown increases.
Back of control panel
External sensor, blue (F)
Load monitor, green (E)
External start of boiler, yellow (D)
Change LPG cylinder (C)
18
B.
9 mm
Remote sensor, white (G)
Pump signal (B)
1
6
2
7
EXT
8
3
9
4
10
5
38,5 mm
+
red
B
C D E F (G) (H) I
J
BZI
R30
+
C8
JP1
JP6
C.
76 mm
73 mm
R3(4x)
Battery Back-up (3V DC) (H)
Window breaker (I)
Heating of reduction valve
(Eis Ex) (J)
C23
JP4

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis