5.2 Fitting/removing the attachable chisels
(Fig. 3)
Plug the required chisel into the mount of the
chisel hammer. Slip the tensioning spring (4) over
the chisel. Turn the tensioning spring onto the
thread of the cylinder as far as the stop. As you do
this, hold the tensioning spring by the front arm.
To change the chisel you must first disconnect the
equipment from the compressed air source. Turn
the tensioning spring off the cylinder of the chisel
hammer by holding it by its rear arm. The chisel
can now be changed as described above.
The chisel shaft should be lubricated with a little
normal lubricating grease from time to time.
5.3 Fitting the needle scaler attachment
(Fig. 4)
To fit the needle scaler attachment, screw it tightly
onto the thread of the cylinder.
6. Operation
6.1 Connecting to a compressed air supply
Connect the nipple (5) to the quick-lock coup-
ling of a compressed air hose (the hose is not
supplied).
Note the maximum permissible operating
pressure of the equipment.
6.2 Working with the chisel hammer
Move the chisel hammer towards the object you
want to work on. Actuate the trigger lever (1) to
start the chisel hammer.
7. Cleaning, maintenance and
ordering of spare parts
Disconnect the compressed air supply from the
equipment before performing any cleaning work.
7.1 Cleaning
Keep all safety devices, air vents and the
motor housing free of dirt and dust as far as
possible. Wipe the equipment with a clean
cloth or blow it down with compressed air at
low pressure.
We recommend cleaning the equipment im-
mediately each time after use.
Clean the equipment regularly with a damp
cloth and some soft soap. Do not use
cleaning agents or solvents; these may be ag-
Anl_TC_PC_45_SPK9.indb 15
Anl_TC_PC_45_SPK9.indb 15
GB
gressive to the plastic parts in the equipment.
Ensure that no water can get into the interior
of the equipment.
7.2 Maintenance
Warning!
Disconnect the equipment from the compressed
air supply before you carry out any maintenance
or cleaning work.
Compliance with the maintenance instructions lis-
ted here will help this quality product provide you
with a long service life and trouble-free operation.
Regular lubrication is essential for your equip-
ment to work properly for a prolonged period of
time.
Regularly check the speed and the vibration level
by simply observing the tool.
Note: Use environmentally friendly compressed
air oil if you want to operate the equipment out-
side the workshop.
The following lubrication options are available:
Lubrication by mist oiler
Connect a mist oiler between the compressed air
source and the equipment (not supplied, available
at retail stores)
By hand
Each time before using the compressed air tool
insert 3-5 drops of special compressed air oil
into the compressed air connection. If the com-
pressed air tool has not been used for several
days you must insert 5-10 drops of special com-
pressed air oil into the compressed air connection
before switching on.
Store your compressed air tool only in a dry room.

Other maintenance

There are no other parts inside the equipment
which require maintenance.
Excluded from the guarantee are:
Wear parts
Damage cause by too much operating pres-
sure.
Damage caused by non-conditioned com-
pressed air.
Damage caused by improper use or unautho-
rized intervention.