Herunterladen Inhalt Inhalt Diese Seite drucken

Charging Phases; Safety Functions; Technical Data - Formula 1 BC240 Originalbetriebsanleitung

Battery charger
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
EN
Charging
phase s
V
A
1
2
3
4
The concept of the charging process is
explained based on a 12 V battery.
Step 1: Condition check
The charger checks the battery
condition and calculates the required
charging parameters.
Step 2: Precharging
The battery is gently charged with a low
charging current to return the battery to
a chargeable state.
Step 3: Soft start
The battery is gently charged with a low
charging current.
Step 4: Base charge with a
constant current
The battery is quickly and safely char-
ged with a consistent current.
Step 5: Base charge with a
constant voltage
The battery is charged at a constant
charge end voltage until it is fully
charged.
Technic al data
Model
Item number
Input
Input current
Charging voltage
(max.)
18
f1.mts-gruppe.com
5
6
7
BC240
10793
220-240 V AC
50-60 Hz
max. 0,45 A
6 V: 7,4 V
6 V +
: 7,6 V
Li-Ion: 7,2 V
12 V: 14,6 V
12 V +
: 14,8 V
LFP: 14,4 V
Step 6: Monitoring
Once the battery is fully charged, the
charging process will stop.
Step 7: Maintenance char-
ging
The charger monitors the battery capa-
city. Once the battery falls below 12.8 V,
the charger will emit a charging pulse.
This maintains the battery's highest
possible charging level.
Safety func-
tions
To avoid damage to charger and bat-
tery, the charger will turn off its own
electronic system and will immediately
reset the system to basic settings in the
case of
short circuit
wrong connection
open circuit
reversed polarity connection
Battery voltage below 3.0 V ±0.5 V
The charger will remain in standby
mode and the display shows the error
indicator.
During the charging process, if the
charger becomes too hot or due to high
ambient temperature, the power output
is automatically reduced. The charger
continues to trickle charge and automa-
tically starts increasing power when the
temperature drops.
BC260
10794
220-240 V AC
50-60 Hz
max. 0,65 A
6 V: 7,4 V
6 V +
: 7,6 V
Li-Ion: 7,2 V
12 V: 14,6 V
12 V +
: 14,8 V
LFP: 14,4 V
BC280
10795
220-240 V AC
50-60 Hz
max. 0,85 A
12 V: 14,6 V
12 V +
: 14,8 V
Li-Ion: 14,4 V
24 V: 28,8 V
24 V +
: 29,0 V
LFP: 28,8 V

Werbung

Inhaltsverzeichnis

Fehlerbehebung

loading

Diese Anleitung auch für:

Bc260Bc280

Inhaltsverzeichnis