Explanation of the LEDs
Description
Standby
Ignition
Pump running
OK
Special function Battery Alert:
If the "Standby" and "OK" LEDs flash simultaneously, the turbine battery needs to be recharged.
All manuals and user guides at all-guides.com
LED is on
Spin up turbine
Glowplug is ON
Fuel pump running
Turbine in governor mode,
turbine rpm can be
controlled by the RPM slider
46
Helicopter mechanics
with model turbine engine
LED flashes
Manual mode active
---
Glowplug faulty
(open circuit)
a) If turbine is running:
Permissible exhaust gas
temperature exceeded.
b) If turbine is off:
control system is in
„Slow-down" state.