Installing the oven
 Put the appliance with the connecting cable first
into the prepared cabinet a bit.
 Do the connection to the hob as well as to the
"Electrical connection"
mains, see
 Insert the oven into the cabinet opening com-
pletely. Make sure that the cables do not re-
stricted (bent, squeezed or twisted).
 Attach and secure the oven by using the supplied
screws on the side walls of the cabinet.
Electrical connection
Information for the authorized expert
WARNING:
 The installation to the mains supply must conform
to the local standards and regulations.
 Improper connection may cause to an electric
shock!
.
2x mounting holes
are located left and
right in the door
frame.
 Before connecting, ensure that the power supply
corresponds with the information on the rating la-
bel (door frame) and the wiring diagram.
 The connection must be made to a 3-phase alter-
nating current with neutral and protective conduc-
tor.
 Select a suitable cord as mains cable, considering
the connection type and rated power of the oven.
 Fix the mains cable in the tension relief.
 Make sure to connect the protective ground to the
terminal of the marked terminal block.
 The electrical installation of the oven should be
equipped with an emergency switch, which
switches off the whole appliance from the mains
supply in an emergency. The distance between
the contacts of the emergency switch must be at
least 3 mm.
 Arrange the mains cable in such a way that it
does not get in contact with any hot components
of the appliance. Do not lead it over sharp edges
or corners.
Connecting the hob to the oven
Insert the plugs at the end of the hob circuit group in
the appropriate socket of the oven terminal block.
Connection wiring diagram
Permissible connection methods
CAUTION:
In any case, the protective conductor must be con-
nected to terminal
NOTE:
L1, L2, L3 = Phase | N = Neutral
= Protective ground
32
.
3N AC 380/400/415 V
For this connection, a
mains cable of type
H05VV-F must be used.