1) Volume control for the audio analysis (on/off switch
2) Jack, 3.5 mm: AC output for the modulated part of the signal, for
audio analysis via PC or headset.
3) Calibrated AC output 1 Volt peak-peak, proportional to the field
strength.
4) Jack, 12-15 Volt DC for charging the battery. AC adapter for 230
Volt/50 Hz and 60 Hz is included. For other Voltages/Frequencies
please get an equivalent local AC adaptor with the output param-
eters 12 – 15 Volt DC / >100mA.
Caution: If an alkaline battery is used, under no circumstances
should the power adapter be connected at the same time, other-
wise the battery may explode.
Measurement ranges
5)
max = 19.99 mW/m²
min = 1999 µW/m²
Scaling differs when applying the optionally available amplifier or damper!
6) Selector switch for signal evaluation. In the peak hold mode, you
can choose a time setting for the droop rate (Standard = "+"). The
peak hold value can be manually reset by pressing (13) "clear".
7) A little bar on the very left of the LCD indicates the unit of the nu-
merical reading:
bar on top = mW/m² (Milliwatts/m²)
bar on bottom = µW/m² (Microwatts/m²)
8) DC output, allows you to connect additional instruments, e.g. data
logging devices for long-term recordings. Scalable to 1 V DC full
scale
.
9) Connecting socket for antenna cable. The antenna is inserted into
the cross slot at the front tip of the instrument.
Power Level Adapter Switch for external optional amplifier or at-
10)
tenuator only
(not part of the standard scope of supply)
of the instrument the switch should be in pos. "0 dB".
position will shift the decimal point to an incorrect position).
11) ON/OFF switch. Using the top switch-position activates the audio
analysis mode.
12) Load indicator
13) Push button to reset peak hold.
readings no longer drop)
14) Switch for selecting the Video Bandwidth.
Switches for rarely used functions are recessed in the casing of
the instrument.
Contents of the package
Meter, attachable antenna incl. cable, rechargeable battery pack (in
the meter), mains adapter, manual.
© Gigahertz Solutions GmbH
(= 19,990 µW/m²)
(Push and hold for 2 seconds or until the
M a d e in G e r m a n y
. ).
. For regular use
(Any other