Open the oven door.
Press in the opposite plastic fasteners of the re-
taining stripe and remove the stripe forwards at
the same time.
Carefully remove the glass pane.
Replace the glass properly after cleaning and dry-
ing it thoroughly.
Press the retaining stripe firmly back into place.
Reversing the bulb
WARNING:
Make sure that the appliance is turned off from
the power supply (fuse).
Allow the lamp to cool down before replacing the
bulb. There is risk of burns!
NOTE:
Use the correct bulb, heat resistant up to 300°C:
Type G9 - 220-240 V~ - 15 W
Unscrew the lamp cover, clean it with a dry cloth.
Change the bulb.
Reattach the lamp cover, check the functionality.
Troubleshooting
Before you contact an authorized specialist
Problem
Possible cause / Action
Unit does not
Check the power supply.
work
Oven lamp
Bulb is defective, was inserted in-
does not
correctly, is not securely seated in
work
the socket, see
bulb".
Strong
Grease residues in the oven
smoke deve-
chamber, switch off the oven, al-
lopment
low to cool before cleaning.
NOTE:
If a problem persists after following the steps above,
contact your distributor or an authorized technician.
Technical Data
Electrical connection............................................
Connection voltage: ...............380-415 V 3N~ 50 Hz
Rated power: ............................................8000 W
Rated current: .........................................3 x 16 A
Protection class: .......................................I / IP20
Dimension H x W x D / Weight...............................
Worktop cutout: ..............................56.0 x 49.0 cm
Hob net weight: ........................................10.8 kg
Cabinet cutout: .................60.0 x 56.0 x min. 55.0 cm
Oven net weight: ......................................30.0 kg
Available accessories..........................................
Telescopic runner set: .................Art. no. 8 979 060
......................................................
The right to make technical and design modifications
during continuous product development remains re-
served.
This appliance has been tested according to all rele-
vant current CE guidelines, such as electromagnetic
compatibility and low voltage directives, and has
34
"Reverse the
(
not supplied)