1) Volume control for the audio analysis
2) Jack, 3.5 mm: AC output for the modulated part of the signal, for
audio analysis via PC or headset (mono).
3) Normed AC output 1 Volt peak-peak, proportional to the field
strength.
4) Jack, 12-15 Volt DC for charging the battery. AC adapter for 230
Volt/50 Hz and 60 Hz is included. For other voltages/frequencies
please get an equivalent local AC adaptor with the output param-
eters 12 - 15 Volt DC / >100mA.
Caution: If an alkaline battery is used, under no circumstances
should the power adapter be connected at the same time, other-
wise the battery may explode.
Measurement ranges
5)
max
= 19.99 mW/m²
med
= 199.9 µW/m²
min
= 19.99 µW/m²
Scaling differs when applying an amplifier or damper!
6) Selector switch for signal evaluation. Standard setting: "Peak". In
the Peak hold mode you can choose a time setting for the droop
rate (Standard = "+"). The Peak hold value can be manually reset
by pressing (14) "clear".
7) A little bar on the very left of the LCD indicates the unit of the nu-
merical reading:
bar on top = mW/m² (Milliwatts/m²)
bar on bottom = µW/m² (Microwatts/m²)
8) DC output for additional instruments, e.g. data logging devices for
long-term recordings (1 V DC full scale, scalable to 2 V DC).
9) Connecting socket for antenna cable. The antenna is inserted into
the cross slot at the top side of the instrument.
Power Level Adapter Switch for external optional amplifier or at-
10)
tenuator only
lar use of the instrument, the switch should be in pos. "0 dB".
other position will shift the decimal point to an incorrect position)
ON/OFF switch.
11)
Load indicator
12)
Signal fraction: "Full" = total signal strength. "Pulse" = pulsed/
13)
amplitude modulated part of the signal. The latter setting mini-
mizes the instrument's noise to a fraction of the normal level (of
importance for particularly small signals).
Push button to reset peak hold.
14)
reading no longer drops)
Switch for selection of the Video Bandwidth. Standard setting:
15)
"VBW Standard"
Switches for rarely used functions are recessed in the casing of the
instrument.

Contents of the package

Meter, attachable antenna incl. cable, rechargeable battery pack (in
the meter), mains adapter, manual.
Seite 20
(= 19,990 µW/m²)
(these are not part of the standard scope of supply)
.
.= On with audio analysis mode.