2.4 Operating Conditions

The electric pump shall be able to operate continuously and normally under the following operating conditions:
1. The ambient temperature does not exceed +40°C
2. The temperature of the medium ranges from 0 to +40°C
3. The pH value of the medium is 6.5~8.5
4. The mass ratio of the solid impurities contained in the medium is not higher than 0.1% and the particle size is not larger
than 0.2mm
5. The voltage and the frequency of the power supply meet the requirements on the nameplate of the electric pump, where
the nominal voltage and frequency are given. The range of the voltage fluctuation is ±10% of the nominal value.
2.5 Pump Wiring Diagramm
The following figures describe the internal wiring details of the single phase electric pumps.