Extraction of combustion air in the room
Create the air intake on the wall (Fig. 14 - PA =Air
Intake), and leave the appliance to withdraw the
room air, making sure to connect the section of
corrugated pipe on the air inlet pipe, if supplied,
fixing it with the strap and folding it slightly
downwards to prevent any resonance effects.
If the rear wall of the appliance is an external wall,
make a hole for the intake of combustion air at a
height of about 20-30 cm from the ground, re-
specting the dimension indications given on the
technical data sheet at "4.3 Technical features"
on page 45.
A non-closable permanent aeration grid must
be placed externally; in areas that are particularly
windy and exposed to weathering, provide rain
and wind protection.
Ensure that the air intake is positioned so that it
won't be accidentally obstructed.
If it is impossible to create an external air intake
in the wall behind the appliance (non-perimeter
wall), a hole must be made in an external wall of
the room where the appliance is positioned.
If it is not possible to create the fresh air intake in
the room, an external hole can be created in an
adjacent room provided it is permanently inter-
connected by means of a transfer grille.
It is prohibited to withdraw combustion air from
a garage, warehouse containing combustible
materials or rooms at risk of fire.