Any type of unauthorised handling or
replacement with non-original spare
parts shall place the safety of the opera-
tor at risk and relieve the manufacturer
of any civil and criminal liability.
It is prohibited to manually load
pellets into the burn pot; this type
of incorrect behaviour may gen-
erate an abnormal amount of un-
burned gas, giving rise to the risk
of explosion inside the chamber.
Unburned pellet deposits in the burn
pot after a failed ignition must be re-
moved before making a new ignition
attempt.
If the burn pot is not cleaned and regu-
larly serviced, malfunctions and explo-
sions may occur inside the appliance.
Be sure to remove all traces of material
and deposits from the holes of the
burn pot and to clean them each time
the ash is emptied or after each failed
ignition attempt. Make sure the burn
pot holes don't decrease in size as this
may have a negative effect on the safe
operation of the appliance.
Do not wash the product with water.
Water may infiltrate the unit and
damage the electrical insulation, caus-
ing electric shocks.
Do not sit/stand in front of the product
in operation for long periods.
Incorrect use of the product or incor-
rect maintenance works may create a
serious risk of explosion in the combus-
tion chamber.
Only use the fuel recommended by the
manufacturer. The product must never
be used as an incinerator.
It is prohibited to use benzene, lamp
fuel, kerosene, liquid firelighter for
wood, ethyl alcohol or similar liquids
to light or rekindle a flame in this ap-
pliance. Keep these liquids at a due
distance from the appliance during
operation.
004778870 - 17/09/2021
ITALIANO
ENGLISH
DEUTSCH
It is prohibited to insert other types
of fuels in the tank other than wood
pellets.
Some tips to avoid corrosion
phenomena:
• carry out routine cleaning operations
to avoid the build-up of ash deposits;
• feed the appliance only with fuel
having the characteristics described
in the section
"3 FUEL CHARACTERIS-
TICS" on page
42;
• Do not use solvents, acids, aggressive
detergents or products to directly
clean the glass or other components
of the product;
• avoid leaving the product in unfavour-
able ambient conditions (humidity,
airborne salinity, storms, etc.);
• if the appliance is not used for long
periods (e.g. during the summer),
disconnect the combustion air inlet
pipe and place dessicant bags in the
combustion chamber to absorb the
humidity in the air, making sure to
remove them when the product is
re-ignited.