PARAMETER
VALUE
Co.tE
no
rESi
Foto
S.EnC
0 - 7
i.Adi
no
Si
Ev.di
Si
no
Ev.M
0 - 5
FinE
no
Si
DESCRIPTION
Test of the safety edges
This menu allows setting the method of control of the safety edges
working
Test disabled
Test enabled for conductive rubber safety edges
Test enabled for optical safety edges
Encoder sensitivity
This menu allows the sensitivity of the rate sensor to be adjusted.
A decreased rate below the set threshold indicates the presence of an
obstacle.
0
If set to
the obstacle is only detected when the gate is stopped.
When the sensor intervenes, the gate stops and is operated in the reverse
direction for 3 seconds to remove the obstacle.
The next start command restarts the movement in the previous direction
Enabling the ADI device
This menu makes it possible to enable operation of the device connected
to the ADI connector.
Si
PLEASE NOTE: selecting
and pressing MENU accesses the
configuration menu for the device connected to the ADI connector.
This menu is managed by the device itself and is different for each device.
Please refer to the manual for the device.
Si
If the
option is selected, but no device is connected, the display will
show a series of dotted lines.
Exiting the ADI device configuration menu returns to the
Interface disabled, any signals will be ignored
Interface enabled
Display of the events
If this function is enabled, every time that an event changes the normal
operation of the gate (coming into action of a safety, control by user, etc.)
the display shows a message indicating the cause.
Function activated
Function deactivated
Storage level of the events
The events are stored in the list of events for diagnosis according to the
set value in this menu:
0
Only the reset and the programming operations
1
Even the errors detected by the various tests (
2
Even the events that change the normal operation of the gate (coming
into action of a safety, control by user, etc.).
3
Even the safeties that have prevented the activation operation cycle
(stop, etc.).
4
Even the controls that have activated an operation cycle (start, etc.).
5
Even the automatic actions of the unit (
End of Programming
This menu allows to finish the programming (both default and
personalized) saving the modified data into memory
Do not quit the programming
End of programming
i.Adi
Err2
Err3
,
En.SA
t.inA
and
- 54 -
DEFAULT
MEMO
no
0
no
option
Si
3
, etc.).
)
no